Parry
-British Built for Purpose
IN244-3
13
Fault Finding
Fault
Check
Solution
No red indicator light
1.
Check that the
appliance is connected
to socket and turned on
2.
Check that the isolator
is turned on.
3.
If fitted with a 3-pin plug
check the fuse.
If the problem continues please
contact your distributor
Red indicator light lit but green
indicator fails to illuminate
when turning the thermostat
Temperature safety thermostat
has not tripped
Reset temperature safety
thermostat as per instructions
below.
Guide to Reset over temperature
Safety Thermostat
Isolate the mains supply
before removing the cover
Remove the 2 screws from the cover to
gain access to the safety thermostat.
(A)
Using a pointed object (ballpoint pen /
Thin screwdriver) insert into the centre of
the thermostat
(B)
press with force and
you will hear/feel the thermostat click
and reset.
Please Note: The oil must be cool before
the safety thermostat can be reset.
If this does not solve the problem, please
contact your distributor.