Parry
-British Built for Purpose
IN107-9
7
Installation Instructions
Where a quick release coupling is used for horizontal travel such as in commercial catering
appliances it is advisable that the coupling is facing downwards to prevent the ingress of
debris and ensure the hose is formed into a smooth curve.
All units should have a restraining cable fitted preventing the unit from being pulled away
from the wall and causing the gas hose to become disconnected accidentally
SAFETY NOTE
Some parts and surfaces of this appliance can get hot in use. It is the responsibility of the
Kitchen Supervisor to inform and warn every user of this and to ensure the user wears any
necessary protective clothing when operating the fryer.
Technical Data
Technical Data
GAS RATE
NATURAL GAS G20 @ 20mbar
0.71 M³/hr
PROPANE G31 @ 37mbar
0.23 M³/hr
INJECTORS
NATURAL GAS
INJECTOR 220
PROPANE
INJECTOR 135
HEAT INPUT (NETT)
NATURAL GAS G20 @ 20mbar
6.84kw
PROPANE G31 @ 37mbar
5.8kw