background image

 

Parry

-British Built for Purpose 

IN107-9

 

21 

  Warranty Information  

 

 

 

 

 

Not covered under warranty 

 

Fault due to incorrect installation, poor maintenance or 

equipment abuse. 

Resetting of equipment or circuit breakers. 

Faulty electrics 

 

e.g. customer’s plug socket, plug, wiring, 

junction box fault, wrong fuse. 

Products must be serviced within the first 12 months to 

be eligible for the 2 year warranty 

Product not covered by warranty if combustible 

materials have been used, e.g. plastic trays. 

Foil used on racks, blockages and lime scale issues. 

 

Failure to grant access for pre-arranged service call.  

Equipment that has been set up or used incorrectly e.g. 

dishwasher detergents, levelling and setting up of 

doors on a six burner cooker. 

Excessive carbon build-up on griddle plates or overuse 

of lava rock on chargrills. (Recommended use by 

Parry no more than 2kg.) 

All of the above points are not covered by warranty and 

any costs incurred, because of the above, will be 

forwarded to the parties responsible for placing 

the call. 

 

The manufacturer’s warranty is only valid in the UK 

mainland. Northern Ireland, Western Isles, Inner 
Hebrides and Islands are parts only warranty. Please 
be aware that the warranty starts from the date of 
purchase from Parry and not the sale or installation 
date of the equipment.  
 
To be eligible for a 2 year warranty, products must be 
serviced at least once within the first 12 months of 
purchase. 
 
All service calls will be carried out between 8am 
and 5pm, Monday to Friday. 
 
Your warranty is invalid if your equipment has not 
been installed in accordance with the 

manufacturer’s instructions. The misuse, alteration 

or unauthorised repairs of the equipment will also 
invalidate the warranty. 
 

During the warranty period it is at Parry’s 

discretion whether to repair or replace the 
equipment. 
The warranty only applies if the equipment has 
been used in a professional manner following the 

manufacturer’s instructions and maintenance 

guidelines.  

 

The warranty covers defects in the material and 
component failure only. We are not liable for trading 
loss, loss of perishable items, water damage or loss 
due to injury or fire damage. 
 
Please ensure you have referred to the 

manufacturer’s instruction before placing a warranty 

call.  
 
Contact our warranty department on 

01332 875544 

for technical assistance.  
 
Please have your model number ready before calling.  
 
All warranty requests must be submitted to 

[email protected]

. 

 
Failure to pay any warranty charges will result in your 
warranty being put on hold until the bill has been 
settled. Any issues regarding the raised charges should 
be put in writing to our warranty department for 
further investigation. 
 
Register your product by visiting our website 

www.parry.co.uk

 

Summary of Contents for AGF

Page 1: ...Instruction Manual AGF AGFP Tabletop Gas Fryer...

Page 2: ......

Page 3: ...hnical Data 7 Operating Instructions 8 10 Cleaning Instructions 11 Maintenance Instructions 12 14 Fault Finding 15 Service Information 16 Exploded View 17 Parts List 18 19 Replacement Parts 20 Warrant...

Page 4: ...ering establishments Simple to clean and operate it s manufactured from stainless steel Supplied with two fryer baskets as standard the fryer is both powerful and reliable Please note this unit comes...

Page 5: ...BTU Natural BTU Propane Butane 23 338 19 790 Input Gas Connection 3 8 BSP Female GAS INPUT PRESSURE Natural GAS INPUT PRESSURE Propane GAS INPUT PRESSURE Propane Butane 20 mbar 37mbar n a Can be conv...

Page 6: ...LD ONLY BE USED BY QUALIFIED PEOPLE The data plate on the rear of the appliance must be checked to ensure the appliance is suitable for the gas supply available This appliance must be installed in acc...

Page 7: ...ase filter All local fire regulations must be observed before the appliance is commissioned the gas safety regulations require that all gas connections on the gas line are tested for gas soundness bet...

Page 8: ...accessible isolation cock should be fitted in the pipework as close as possible to the fryer An approved flex may be used in conjunction with a straining cable The parts protected by the manufacturer...

Page 9: ...from being pulled away from the wall and causing the gas hose to become disconnected accidentally SAFETY NOTE Some parts and surfaces of this appliance can get hot in use It is the responsibility of...

Page 10: ...to the required cooking temperature Already Solidified in the Pan Light the appliance and turn the thermostat ON for approximately 5 10 seconds and then turn OFF again Leave it for 30 seconds before r...

Page 11: ...turned to the required cooking temperature allow the oil or fat to heat up for about 30 35 minutes before starting to cook After each load is removed from the fryer always allow 7 minutes for the tem...

Page 12: ...quality oil or fat which has high breakdown temperature Use only clean oil or fat and strain daily Maintain the oil or fat at the correct level Do not start to fry until the oil has reached the corre...

Page 13: ...Clean the drain tube assembly using a tube or flue brush suitable for 15mm tube with the drain tap in the open position Clean by inserting brush into inlet and outlet of drain tube Wash all parts thor...

Page 14: ...w parry co uk parry commercial catering spares The use of old oil or food with a high moisture content can reduce the flash temperature and can cause overheating of the oil Fryers should never be left...

Page 15: ...rained and filtered each day it is used This will prolong the life of the oil ROUTINE MAINTENANCE To be carried out by an engineer Ensure fryer is filled with oil Fit pressure gauge to multifunction v...

Page 16: ...ilure valve closes within 60 seconds This can be done by feel or sound Turn off the gas remove pilot and withdraw burner assembly clean the burner parts and ensure the injectors are clear Reassemble t...

Page 17: ...pilot position Yes Check over temperature stat for open circuit and then check thermocouple voltage min 15mv Yes very little Check supply then check pilot jet for blockages and clean if necessary No...

Page 18: ...person Enhanced 2 Years Warranty Parry Catering Midlands Ltd offer an enhanced warranty of two years including parts and labour on all of the Parry manufactured products To take advantage of this you...

Page 19: ...Parry British Built for Purpose IN107 9 17 Exploded View...

Page 20: ...CHBS02700 10 Basket Handle HANDLEBASK 11 Fryer Tank No Code 12 Fryer Top No Code 13 Tee Knob TEEKNOB 14 Lid No Code 15 Batter Plate No Code 16 Flue Cover No Code 17 Back Panel No Code 18 Burner Box No...

Page 21: ...Disc QTY 2 DISC067061 Hex Nut LNUT05501 Split Bush NIPP67061 Graphite Seal SEAL07000 Fibre Washer QTY 2 WASH05505 Pilot Pipe AGFPILOTP 6mm Shear Off Olive and Nut SIT6MMSHEAR Burner Pipe AGFBURNRP Co...

Page 22: ...LVE AND THERMOSTAT Drain fryer Disconnect the gas supply pipe work and pipe to burners See previous notes for removal of pilot thermocouple assembly Untighten the gland fitting to release phial from t...

Page 23: ...llation date of the equipment To be eligible for a 2 year warranty products must be serviced at least once within the first 12 months of purchase All service calls will be carried out between 8am and...

Page 24: ...Parry British Built for Purpose IN107 9 22 Disposal Recycling The packaging should be disposed of in accordance with the regulations in force...

Reviews: