Parry
-British Built for Purpose
IN107-9
20
Replacement Parts
PILOT JET AND ELECTRODE
Undo pilot feed from gas valve, undo thermocouple from valve, remove screw from pilot
bracket, pilot assembly, c/w thermocouple and ignitor can now be removed.
THERMOCOUPLE
Undo thermocouple from gas valve; release probe end from the bracket on the pilot
assembly. Fit new in reverse order.
CONTROL VALVE AND THERMOSTAT
Drain fryer
Disconnect the gas supply pipe work and pipe to burners.
See previous notes for removal of pilot/thermocouple assembly.
Untighten the gland fitting to release phial from the tank.
Remove screws securing valve to bracket.
Remove fittings from valve to fit into replacement valves, as these are
not supplied with new valve.
Refit in reverse order.
SAFETY THERMOSTAT
Drain fryer
Remove spade connections on thermostat
Remove the nut securing thermostat to fascia
Untighten the gland fitting to release phial from the tank.
Fit new thermostat in reverse order.