GB
9
앬
The walls in the immediate vicinity of
stationary workplaces may not have a light
color or a sheen. Windows up to head
height are to be protected against radiation
passing through them or reflecting off them,
for example by coating them with a suitable
paint.
4. Symbols and technical data
EN 60974-6
European standard for arc
welding sets and welding
power supplies with limited
on time (part 6).
Symbol for welding power
supplies which are suitable
for welding in
environments with
increased electrical
danger.
~ 50 Hz
Alternating current and
rated frequency value [Hz]
U
0
Rated idling voltage [V]
40A/19.6V - 80 A/21.2 V
Maximum welding current
and the corresponding
standardized operating
voltage [A/V]
Ø
Electrode diameter [mm]
I
2
Welding current [A]
t
w
Average load time [s]
t
r
Average reset time [s]
Line input; number of
phases, the alternating
current symbol and the
rated frequency value
Do not store or use the
equipment in wet or damp
conditions or in the rain.
Use the equipment only
indoors.
U
1
Line voltage [V]
I
1max
Highest rated value of the
line current [A]
I
1eff
Effective value of the
highest line current [A]
IP 21S
Protection type
H Insulation
class
Mains connection:
230 V ~ 50 Hz
Welding current (A) at cos ϕ= 0.73:
40 - 80
ø (mm)
1.6 2.0 2.5
I
2
40 55 80
t
w
(s)
217 116 64
t
r
(s)
1450 1381 1351
Idling voltage (V):
48
Power input:
4 kVA at 80 A cos ϕ = 0.73
Fuse (A):
16
Weight: 10.6
kg
The welding times apply for an ambient
temperature of 40° C.
5. Assembling the welding
screen (fig. 2-5)
Insert the safety glass (9) and then the welding
glass (10) in the welding screen (8). Now fasten
the welding screen holder (11) to the welding
screen, as shown in fig. 5.
1~ 50 Hz
S
Anleitung_1549052:_ 15.12.2009 14:47 Uhr Seite 9
Summary of Contents for 45846
Page 3: ...3 1 2 1 9 10 11 8 5 6 7 8 2 3 4 3 8 9 12 Anleitung_1549052 _ 15 12 2009 14 47 Uhr Seite 3 ...
Page 4: ...4 4 5 11 10 8 Anleitung_1549052 _ 15 12 2009 14 47 Uhr Seite 4 ...
Page 12: ...GB 12 13 Circuit diagram Anleitung_1549052 _ 15 12 2009 14 47 Uhr Seite 12 ...
Page 22: ...DK 22 13 Forbindelsesdiagram Anleitung_1549052 _ 15 12 2009 14 47 Uhr Seite 22 ...
Page 25: ...25 Anleitung_1549052 _ 15 12 2009 14 47 Uhr Seite 25 ...
Page 26: ...26 Anleitung_1549052 _ 15 12 2009 14 47 Uhr Seite 26 ...
Page 27: ...27 Anleitung_1549052 _ 15 12 2009 14 47 Uhr Seite 27 ...