6 GB
Introduction / General safety advice for electrical power tools
Introduction
Paint spray gun PFS 100 C3
Q
Introduction
We congratulate you on the purchase of your new
device. You have chosen a high quality product. The
instructions for use are part of the product. They
contain important information concerning safety,
use and disposal. Before using the product, please
familiarise yourself with all of the safety information
and instructions for use. Only use the unit as descri-
bed and for the specified applications. If you pass
the product on to anyone else, please ensure that
you also pass on all the documentation with it.
Q
Proper use
This device is intended for applying paints, varnishes
and glazes. This device can be used to apply spray
material with a flow time of max. 80 seconds. Any
other use or modification shall be deemed to be im-
proper use and could give rise to considerable risk
of accident. We will not accept liability for loss or
damage arising from improper use. The device is
intended for private, domestic use only.
Q
Features and equipment
1
Attachment screw
2
Regulator button
3
ON / OFF switch
4
Pump piston
5
Spring
6
Suction tube
7
Paint cup
8
Nozzle
9
Suction-pressure valve
10
Pump housing
11
Metal stirrup
12
Cleaning nozzle
13
Viscosity measuring cup
14
Nozzle extension
Q
Included items
1 Paint spray gun PFS 100 C3
2 Nozzles* 1 x 0.6 mm, 1 x 0.8 mm
2 Suction pressure valves*
1 Cleaning nozzle
1 Nozzle extension
1 Viscosity measuring cup
1 Operating instructions
* 1 x prefitted
Q
Technical data
Rated power:
100 W
Rated voltage:
230 V~ 50 Hz
Delivery capacity:
320 g / min (water)
Pressure:
max. 160 bar
Paint cup:
700 ml
Protection class:
II /
Noise and vibration data:
Measured values for noise are determined in accor-
dance with EN 60745. The A-weighted noise level
of the electrical power tool are typically:
Sound pressure level: L
pA
= 90.77 dB(A)
Uncertainty K:
3 dB
Sound power level: L
WA
= 101.77 dB(A)
Uncertainty K:
3 dB
Wear ear protection!
Total vibration value of the handle a
h
16.55 m / s
2
Uncertainty K = 1.5 m / s
2
The vibration level given in these
instructions has been measured in accordance with
a standardised measurement procedure specified in
EN 60745 and can be used to compare devices.
Different uses of the device give rise to different vi-
bration levels and in many cases they may exceed the
values given in these instructions. It is easy to under-
estimate the vibration load if the electrical power
tool is used regularly in particular circumstances.