9.
CHECKING LID CUT-OFF DEVICE
1.
Lift the lid.
2.
Turn one hotplate burner tap to its full on position and push the ignition button.
3.
Close lid. There should now be no gas supply to the hotplate and the burner will go out.
4.
Turn off the hotplate tap and lift the lid. The gas supply should now be restored to the hotplate when the
tap is turned on.
10. CHECKING THE MAIN OVEN
1.
Turn the oven thermostat knob to Mk 9 and press the ignition button. As soon as the burner is alight the
button can be released.
2.
There should now be a low gas rate to the burner, which is the F.S.D. by pass rate.
3.
When the F.S.D. phial has heated up it opens the F.S.D. valve which allows the main gas supply to the
oven burner.
4.
After 1 minute check that the flame covers the full width of the burner and is stable.
5.
Set the oven control to Mk 2, close the oven door and check that after about 10 minutes the flame size
has reduced.
6.
Turn off the control and check that the oven flames go out.
GENERAL NOTE
Instruct the
user
on how to
use the appliance and its ignition system. Refer the user to the wording in the
inside cover of this Instruction Booklet which gives advice on the safe operation of the appliance.