Parker V758P Instruction And Installation Sheet Download Page 1

V758P

 

Instruction and Installation Sheet                        

 

PXM 

 

Introduction 

Follow these instructions when installing, operating, or 
servicing the product. 
 

Installation & Operating Instructions: 

The Pilot Exhaust Module (PXM) is installed between an 
HA (ISO size 01) valve and a manifold segment. This 
valve in conjunction with PXM controls the presence of 
14 pilot control pressure in a specific pressure zone in 
the manifold. This valve and PXM must be mounted in 
the pressure zone.  
 
The pressure zone begins at a segment with the left 
gasket pilot ports 12 & 14 blocked. The pressure zone 
ends at either the right end plate of the manifold or at the 
next segment with the pilot ports 12 & 14 blocked. If a 
high flow end plate is the end

 

of the pressure zone, the 

12 & 14 ports must be plugged in the end plate. 
 
Minimum operating pressure of the HA valve on the PXM 
must be present in the main pressure galley (port 1) of 
the manifold

 

segment. Valves with pilots controlled in the 

pressure zone must be externally piloted to the 14 pilot 
port, and 2 position single solenoid valves must have a 
spring return mechanism incorporated in the 12 end 
return operator.  Any valve in this zone configured as 
internally piloted or using sandwich regulator will NOT 
have their pilot pressure controlled by the PXM. 

 

These conditions will be seen at the externally piloted 
valves with solenoids energized and PXM has exhausted 
zoned pilot pressure: 
 

 

5/2 Single Solenoid valves (with mechanical 
spring) will shift to the 12 position. 

 

5/2 Double Solenoid valves will remain in the 
“last energized state". 

 

5/3 Double Solenoid valves will shift to the 
“center position”. 

 
Lubrication 

Factory pre-lubed. If lubricating in service, use Parker 
F442 oil or equivalent paraffin based mineral oil with 150 
to 200 SSU viscosity @100°F. 
 

CAUTION: Do not use oils that are synthetic, 
reconstituted, have an alcohol content or a detergent 
additive. 
 

Application Limits 

These products are intended for use in general purpose 
compressed air systems only. 

Operating Pressure Range: 

Maximum 145 PSIG (1000 kPa) 

Ambient Temperature Range: 

-15°C to 49°C (5°F to 120°F 

Installation: 

 

Install Pressure 
Switch 

1. Remove Plug (3) 
and Plug Gasket (2) 
from body.  Separate 
the Plug Gasket (2) 
from Plug (3). 

 
 

 

Item 

Description 

ISO Pilot Exhaust 
Module (PXM) Base 

Plug Gasket 

Plug 

Pressure Switch 