Technical data
104 (109)
192-011006N8 2019-07
09.10.19 09:27
8.8
Insulation requirements PSD1
Category
Specifications
Protection class
Protection class in accordance with EN 60664-1
Protection against
human contact with
dangerous voltages
In accordance with EN 61800-5-1
Overvoltage Category
Voltage category III in accordance with EN 60664-1
8.9
Environmental requirements PSD1
Category
Specifications
General ambient
conditions
According to
EN 60 721-3-3
Climate (temperature/humidity/barometric pressure): Class 3K3
Permissible ambient
temperatures:
Mode of
operation
0 to +40 °C
Class 3K3
Storage
–25 to +70 °C
Transport
–25 to +70 °C
Tolerated humidity:
Operation
<= 85% Class 3K3
Storage
<= 95 %
Transport
<= 95 %
(Relative humidity)
Elevation of operating
site
<=1000m above sea level for 100% load ratings
<=2000m above sea level for 1% / 100m power reduction
please inquire for greater elevations
Sealing
Type of protection IP20 according to EN 60 529
Mechanic resonances:
With packaging (transport/ storage): 10 m/s
2
; 9 – 200 Hz
Without packaging: 10 m/s
2
; 57 – 150 Hz
Pollution degree
Degree of contamination 2 in accordance with EN 60664-1 and EN 61800-5-1
8.10
cUL certification
Category
Specifications
PSD1M:
UL508C, 3rd Edition, power supply load revision November 9th, 2010.
C22.2 N°.274-13, 12th Edition, last revision March 2013.
PSD1S:
UL61800-5-1 1st Edition, issued June, 8th, 2012
C22.2 No.274-13, 1st Edition, issued March, 2013
Certified
E-File_No.: E142140
The cUL approval is documented by a “UL” logo on the device (type specification plate).
8.11
EtherCAT characteristics
Category
Specifications
Profile
Motion Control CiADS402
Baud rate
100 MBits (FastEthernet)
Service data object
SDO
Cycle Time
>=1 ms
Synchronicity accuracy
maximum jitter: +/-25µs