Plug and device overview PSD1-M
16 (31)
192-011003N7 DOC-0001-01-B
11.12.23 11:39
4.2
View from below (PSD1-M)
View from above
(see page 18)
X45
X43 for PSD1M_1800
Motor connections: Axis 1 ... 3 (depending on the device)
X46
X44 for PSD1M_1800
Motor brake connections: Axis 1 ... 3 (depending on the device)
X48
Connection of HIPERFACE DSL® motor feedback systems and
motor temperature sensor
Axis 1 ... 3 (depending on the device)
Front view
(see page 15)
Shows pin 1 of the connector
Earthing PSD1M_1800:
Explanation
1
DSL connection
2
Connection of motor brake
3
Connect ground via ring cable lug
with a 10 mm
2
copper cable to
central ground
4
Mounting the
shield clamp
1)
with
flat connection to the motor cable
shielding
5
Motor Connection
1)
The
shield clamp
is supplied with
the Parker motor cables.
An accessory set with several
clamps for various possible cable
diameters is optionally available for
in-house manufactured motor
cables.