Parker Pro Display 10 Instruction Book
21/53
PRO DISPLAY
CAMERA
SUPPLY
12V_CAM
GND
I Max= 1A
CAMERA
C5:2
C5:3
Figure 10: Camera supply output. When there is second camera in the end application, the
branching of the supply wires shall be implemented in a wire harness – see more about
this in figure 7, chapter 4.4.
4.5.4. Digital output
One high-side output is available, providing 200mA max. output current. This output can
be used, for example, as an audio amplifier wakeup, to control an external buzzer or for
signalling other external devices.
Table 13: High-side output specifications
Feature
Spec
Output current
200mA
ON- state
VBatt – 0,7V (100mA load)
VBatt – 0,25V (no load)
OFF- state
0V (100mA load)
0,15V (no load)
PRO DISPLAY
HSIDE_OUT
HS OUT
I Max= 200mA
EXTERNAL
DEVICE
SECONDARY
CIRCUIT
GND
C2:6
C2:7
Figure 11: High-side output connection principle. This shows just one use case for this
output; an external device can also be an indicator etc.
4.6. Communication
4.6.1. CAN
Pro Display has four CAN buses (ISO 11898). These buses can be used with various
protocols, according to OEM’s needs. Parker currently supports J1939 protocol in Pro
Display. OEM can implement other necessary protocols. All CAN buses have software-
controlled termination.
NOTICE: Internal CAN termination is controlled by application software and
therefore it is not enabled during boot-up. This shall be taken into account in end