13
5.4.2 OIL-X Element Change Procedure
A
Ensure that the filters are fully depressurised by opening the manual drain.
B
Unscrew the filter bowl and remove the used element.
C
Replace the o-ring located on the filter bowl with the new one provided within the 12
month Preventative Maintenance kits.
D
Insert the new element into the filter bowl ensuring that the lugs are correctly seated in
the grooves.
E
Refit the filter bowl to the head ensuring that the threads are fully engaged and the
locking details are aligned.
F
Close the manual drain and re-pressurise the system.
We recommend the use of gloves when touching contaminated elements.
Ensure to lubricate the o-ring and threads with Molykote III grease.
Item
Description
Item
Description
1
Filter head
4
Filter bowl o-ring
2
Filter bowl
5
Manual Drain
3
Element
1
2
3
4
5
Summary of Contents for PCO2