Overview
24
2.8
Network Communication Ports
NT1 and NT2
The Network Communication Ports are used to connect the PCH Portal to external devices in the
automation system.
Network Interface
M12, D-coded, female
Pin No.
Function
1
Tx+
2
Rx+
3
Tx-
4
Rx-
2.9
Connection to H Universal Air Supply
There are 2 connectors (30 pin and 10 pin) for up to 32 valves. 24 valves can be connected to 30
pin connectors and 8 valves can be connected to 10-pin connector. Each valve output has a
maximum of 160 mA at 24 V.
Valve Output Pinout:
Valve Output Pinout