PACIO MODULES
138
Parker Automation Controller Installation Guide
Module Control
The Module provides no operational options but a PROFIBUS-address, which is set by the EtherCAT-
master. The Module indicates errors by different "Module state" bits. These error bits are stored. To reset
the error bits, set control bit "ResetError" to a rising edge.
Variable
Data type
Explanation
SetOptions
BOOL
Rising edge
accepts the PROFIBUS address
ResetError
BOOL
Rising edge
acknowledges error
SPC3 Address
The PROFIBUS-DP-Slave address is set by the following variable. The assumption of the address is
released with the rising edge of SetOption. The execution is indicated with OptionSet. The PROFIBUS DP
slave address also can be changed at runtime.
Variable
Data type
Explanation
Address
USINT
PROFIBUS-DP-Slave address
Module State
The following Module states are indicated below. To reset the messages, see
above.
Variable
Data type
Explanation
Shortcut
BOOL
not used
Undervoltage
BOOL
not used
Watchdog
BOOL
Internal watchdog of Module
EtherCAT_Error
BOOL
Configuration error or watchdog control
Specific_Error
BOOL
not used
OptionsSet
BOOL
Sent by Module to acknowledge SetOptions
Module-Specific Messages
Apart from the Module error messages, there is a set of messages containing details about the current
state of the Module.
Variable
Data type
Explanation
ProfibusRunning
BOOL
PROFIBUS runs
Configuring the Data Modules
For the configuration of the EtherCAT and the PROFIBUS, the appropriate configuration files are needed.
These are:
ParkerEtherCATModules.xml for EtherCAT
Park6943.GSD for PROFIBUS
Number and size of the data Modules are configurable. The relationship of input data and output data is
always thereby 1:1. Select the desired data Modules in the respective Configurator tools.
Summary of Contents for PAC
Page 11: ...CHAPTER 1 Product Overview...
Page 18: ......
Page 19: ...CHAPTER 2 Installation...
Page 33: ...CHAPTER 3 System Start up and Configuration...
Page 69: ...CHAPTER 4 PACIO Modules...
Page 143: ...2 After adding the device and code to the project you will configure the IO map as displayed...
Page 155: ...PAC with 400XR series...
Page 156: ...PACIO MODULES 156 Parker Automation Controller Installation Guide...
Page 157: ...PAC with 400LXR...
Page 158: ...PACIO MODULES 158 Parker Automation Controller Installation Guide PAC with SMH sensors...
Page 159: ...CHAPTER 5 Communication Interfaces Optional...
Page 176: ......
Page 177: ...CHAPTER 6 Troubleshooting...
Page 188: ...TROUBLESHOOTING 188 Parker Automation Controller Installation Guide...
Page 189: ...APPENDIX A PAC System Specifications...
Page 195: ...APPENDIX B Additional Information...