Parker Hannifin
P Series User Guide
84
Inertia
10250
0x280A
[Third Party Motor]
Torque Constant
0x2807
FP32
0.46
-
-
Kg.m2.
10-4
RW
10252
0x280
C
[Third Party Motor]
Phase Resistance
0x2808
FP32
0.82
-
-
ohm
RW
10254
0x280E
[Third Party Motor]
Phase Inductance
0x2809
FP32
3.66
0
1000
Mh
RW
10256
0x2810
[Third Party Motor] TN
Curve Data 1
0x280A
UINT
3000
1
60000
rpm
RW
10258
0x2812
[Third Party Motor] TN
Curve Data 2
0x280B
FP32
100
-
-
%
RW
10260
0x2814
[Third Party Motor]
Hall Offset
0x280C
UINT
0
0
360
deg
RW
Table 43. 3
rd
Party Motor Parameters
4.3.10 CiA402 Parameters
communication
address
parameter name
parameter
No.
Variable
Format
Default
Value
Min
Max
Unit
Accessibility
decim
al
hexadec
imal
24576
0x6000
Error Code
0x603F
UINT
0
-
-
-
RO
24577
0x6001
Control word
0x6040
UINT
0
0
65535
-
RW
24578
0x6002
Status word
0x6041
UINT
-
-
-
-
RO
24579
0x6003
Quick Stop Option
Code
0x605A
INT
2
0
4
-
RW
24580
0x6004
Shutdown Option
Code
0x605B
INT
0
1
1
-
RW
24581
0x6005
Disable Operation
Option Code
0x605C
INT
1
0
1
-
RW
24582
0x6006
Halt Option Code
0x605D
INT
0
0
4
-
RW
24583
0x6007
Fault Reaction
Option Coed
0x605E
INT
0
0
0
-
RW
24584
0x6008
Modes of Operation
0x6060
SINT
0
0
10
-
RW
24585
0x6009
Modes of Operation
Display
0x6061
SINT
-
-
-
-
RO
24586
0x600A
Position Demand
Value
0x6062
DINT
-
-
-
UU
RO
24588
0x600C
Position Actual
Internal Value
0x6063
DINT
-
-
-
Pulse
RO
24590
0x600E
Position Actual
Value
0x6064
DINT
-
-
-
UU
RO
24592
0x6010
Following Error
Window
0x6065
UDINT
600000
0
1073741
823
UU
RW
24594
0x6012
Following Error
Timeout
0x6066
UINT
0
0
65535
ms
RW
24595
0x6013
Position Window
0x6067
UDINT
100
0
1073741
823
UU
RW
24597
0x6015
Position Window
Time
0x6068
UINT
0
0-
65535
ms
RW
24598
0x6016
Speed Demand
Value
0x606B
DINT
-
-
-
UU/s
RO
24600
0x6018
Speed Actual Value
0x606C
DINT
-
-
-
UU/s
RO
24602
0x601A
Speed Window
0x606D
UINT
20000
0
65535
UU/s
RW
24603
0x601B
Speed Window Time
0x606E
UINT
0
0
65535
ms
RW
24604
0x601C
Target Torque
0x6071
INT
0
-5000
5000
0.1%
RW
24605
0x601D
Maximum Torque
0x6072
UINT
3000
0
5000
0.1%
RW
24606
0x601E
Torque Demand
Value
0x6074
INT
-
-
-
0.1%
RO
24607
0x601F
Torque Actual Value
0x6077
INT
-
-
-
0.1%
RO
24608
0x6020
Target Position
0x607A
DINT
0
-
21474
83648
2147483
647
UU
RW
www.comoso.com
Summary of Contents for P Series
Page 16: ...Parker Hannifin P Series User Guide Change Summary www comoso com...
Page 60: ...Parker Hannifin P Series User Guide 58 3 11 3 I O Signal Wiring www comoso com...
Page 292: ...Parker Hannifin P Series User Guide 290 www comoso com...
Page 293: ...Parker Hannifin P Series User Guide 291 Figure 60 FCL Series N T Curves www comoso com...
Page 294: ...Parker Hannifin P Series User Guide 292 10 5 FE Series N T Curves www comoso com...
Page 295: ...Parker Hannifin P Series User Guide 293 www comoso com...
Page 296: ...Parker Hannifin P Series User Guide 294 www comoso com...
Page 297: ...Parker Hannifin P Series User Guide 295 www comoso com...
Page 298: ...Parker Hannifin P Series User Guide 296 www comoso com...
Page 300: ...Parker Hannifin P Series User Guide 298 www comoso com...
Page 301: ...Parker Hannifin P Series User Guide 299 Figure 62 FF Series N T Curves www comoso com...