1 6
OEM6250 Installation Guide
General-Purpose Programmable Inputs & Outputs
PIN OUTS & SPECIFICATIONS
Pin
Function
Internal Schematics
Specifications
1
2
49
50
PROGRAMMABLE INPUT/OUTPUT
50-pin plug is
compatible with
VM24 and
OPTO-22™
signal
conditioning
equipment.
1
Input #16
(MSB of inputs)
3
Input #15
5
Input #14
7
Input #13
9
Input #12
11
Input #11
13
Input #10
15
Input #9
17
Output #8
(MSB of outputs)
19
Output #7
21
Output #6
23
Output #5
25
Input #8
27
Input #7
29
Input #6
31
Input #5
33
Output #4
35
Output #3
37
Output #2
39
Output #1
(LSB of outputs)
41
Input #4
43
Input #3
45
Input #2
47
Input #1
(LSB of inputs)
49
+5VDC
Inputs
74HCxx
6.8 K
W
47 K
W
Input
Connection
Ground
Connection
IN-P
GND
OEM6250
GND
GND
External 5-24VDC Supply
(an alternative to using the
in5V supply)
R12
(0 K
W
)
+5VDC
If you wish the inputs
to be pulled up to a
voltage other than the
internally supplied
+5V, remove R12 on
the OEM6250 PCB
and connect IN-P to an
external supply of up
to 24VDC.
Outputs
4.7 K
W
Output
Connection
Ground
Connection
OUT-P
GND
OEM6250
External 5-24VDC Supply
(an alternative to using the
in5V supply)
7406
Open
Collector
ISO
GND
R13
(0 K
W
)
+5VDC
GND
GND
If you wish the outputs
to be pulled up to a
voltage other than the
internally supplied
+5V, remove R13 on
the OEM6250 PCB
and connect OUT-P to
an external supply of
up to 24VDC.
Inputs
HCMOS-compatible voltage levels
(Low
£
1.00V, High
³
3.25V).
Voltage range = 0-24V.
Sourcing Current: Leave as is to use the
internally su5VDC pull-up supply, or
remove R12 and connect
IN-P
to an external
5-24VDC power supply.
Sinking Current: On the
AUX
connector,
connect
IN-P
to
GND
(remove R12 first).
STATUS: Check with
TIN
or
INFNC
.
Active level: Default is active low, but can
be changed to active high with the
INLVL
command.
Outputs
Open collector output.
Max. voltage in the OFF state (not sinking
current) = 24V; max. current in the ON state
(sinking) = 30mA.
Pull-up connection on
AUX
connector:
Leave as is to use the internally supplied
+5VDC pull-up supply, or remove R13 and
connect
OUT-P
to an external 5-24VDC
power supply.
STATUS: Check with
TOUT
or
OUTFNC
.
Active level: Default is active low, but can
be changed to active high with the
OUTLVL
command.
NOTE: All even-numbered pins are connected to a common digital ground — see drawing on page 5.
LSB = least significant bit; MSB = most significant bit
CAUTION
:
If you fail to remove the resistor (R12 for inputs, or R13 for outputs) before connecting an
external supply to the inputs pull-up terminal (
IN-P
) or the outputs pull-up terminal (
OUT-P
),
you will damage the OEM6250.
R12 & R13 Resistor Locations
R12
R13
RP240
TH1
NOTE
: You must first
remove the resistor
(R12 for inputs, or R13
for outputs) before you
can connect an external
supply to the inputs
pull-up terminal (IN-P)
or the outputs pull-up
terminal (OUT-P);
otherwise, you will
damage the OEM6250.
VM50 ADAPTOR —
for screw-terminal connections
JOYSTICK
RP240
PROGRAMMABLE INPUTS/OUTPUT
2
4
6
8 10 12 14 16 18 20
1
3
5
7
9 11 13 15 17 19
22 24 26
23
28
25
30
27
32
29
34
31
36
33
38
35
40
37
42
39
44
41
46
43
48
45
50
47 49
21
VM50 Adaptor Board
The VM50 snaps
on to any standard
DIN rail.
Color stripe
(pin #1)
Pin outs on the
VM50 are identical to
the pin outs for the
50-pin connectors
(only if the cable is
connected as
illustrated).
2-Foot Cable
(provided with VM50)
Color stripe
(pin #1)