K3.1.141e Manual NitroFlow HP_EN.doc
- 36 -
6.2.6 Options menu
Access:
Touch options menu button in settings screen
Function:
Set various options (auto restart, remote and pin code)
ATTENTION: All options are default set to NO.
Button Selection
Result
Auto R.
(= auto restart)
Yes
Return to the same situation/status after a power
failure
Auto R.
(= auto restart)
No
After a power failure unit will return in status OFF
and has to be restarted manually (not automatically)
Remote
Yes
Unit can be controlled from a remote location. Only
select YES after connecting an external device to the
printboard (refer to §5.8.1). This external device has
to be a voltage free switch or relay contact. Unit can
now be started from a remote location by closing the
contact/switch. By opening the contact/switch the
unit will be stopped.
If REMOTE is set to YES and there is no remote
signal available the generator will not start.
Remote
No
Unit cannot be controlled from a remote location.
Pin code
Yes
Settings are instantly protected with a pin code.
If
adjustment of all settings is required return to
log on
menu
(refer to §6.2.3) and enter personal pin
code (or default pin code (1234) in case no personal
code is used)
Pin code
No
Settings can be changed without a pin code
Pin code
Change
Pin code can be changed to a personal code.
(In
case you forget your pin code refer to §6.2.3).
Screen where date and time can be set will appear
(see below)