29
IQAN-LC5-C0x Technical Overview
Appendix A
Instruction book, IQAN-LC5-C0x
Appendix A
IQAN-LC5-C0x Technical Overview
IQAN-LC5-C01, base and -MP handle
Absolute Maximum Ratings
a
a.The “Absolute Maximum Ratings” table lists the maximum limits to which the device can be subjected without damage.
This doesn´t
imply that the device will function at these extreme conditions,
only that, when these conditions are removed and the device operated
within the “Recommended Operating Conditions”, it will still be functional and its useful life won’t have been shortened.
Parameter
Remark
Ambient temperature,
T
A
-40 to 85 °C
Storage temperature
-40 to 100 °C
Maximum voltage supply on +BAT
6 to 36 V, no system reset, power drivers will saturate at low voltage
Voltage on any pin with respect to -BAT
36 V
External magnetic fields
2.5 mT
Environmental ratings
Parameter
Remark
EMC
Radiated emission
Conducted emission
Conducted susceptability
Radiated susceptability
Conducted transients susceptability
ISO 13766:2006/ISO 14982:1998
EN 55025:2003, 0.15-108 MHz Class 2
ISO 11452-4:2005, 1 - 200 MHz, 1 kHz, 80% AM, 100 mA
ISO 11452-2:2004, 200-2000 MHz, 1kHz, 80% AM, 100 V/m
ISO 7637-2:2004, Pulse 1, 2a, 2b, 3a, 3b, 4, 5, Level 3
ISO 7637-3:2007, Level 3
ESD
Operation
Handling
ISO 10605:2008, 8 kV contact, 25 kV air
ISO 10605:2008, 4 kV contact
Mechanical environment
Random vibration
Shock
IEC 60068-2-64:2008 Fh, 15 - 1000 Hz, 11.6 Grms, 3 x 10 hours
IEC 60068-2-27:2008 Ea, 40 g, 6 ms, 1000 * 6 directions
Climate environment
Enclosure, water and dust protection
Salt mist
Damp heat, cyclic
Damp heat, steady state
Heat, operation
Heat, storage
Cold
Change of temperature
IEC 600529:2001, IP65 (with sealed handle and bellow)
IEC 68-2-52:1996 Kb, 72 hours (not tested)
IEC 60068-2-30:2005 Db, +55°C, 95% RH, 6 cycles
IEC 60068-2-78:2001 Cab, +40°C, 93% RH, 21 days
IEC 60068-2-2:2007 Bb, 85°C, 72 hours
IEC 60068-2-2:2007 Bb, 100°C, 72 hours
IEC 60068-2-1:1993 Ab, -40°C, 16 hours
IEC 60068-2-14:1984 Nb, -30°C to +85°C, 100x4 hours
System
T
A
= +25 °C (unless otherwise specified)
Parameter
Remark
Weight
Base
Base with -MP handle
380 g
750 g
Ambient temperature
-40 to 85 °C