xxvi
Error codes, messages and actions
Appendix B
Instruction book, IQAN-Lx
Appendix B
Error codes, messages and actions
If one of the following errors are detected, a message will be presented on the master
display together with an error code on the module. In some cases, the module will turn
off, to increase safety.
W
ARNING
Don’t use the machine if an error message or error code is activated.
The following sections will present what measures to take for different error situations
put into appropriate context.
LOW/ HIGH SUPPLY VOLTAGE
VREF ERROR
MODULE IS OFFLINE
Situation
Error code
Action Lx
Comment
+BAT < 8,5 V
Error 1
-
Check voltage supply
+BAT > 34 V
Error 1
-
Check voltage supply
Situation
Error code
Action Lx
Comment
VREF < 4,9 V
Error 1
-
Check voltage
VREF > 5,1 V
Error 1
-
Check voltage
Situation
Error code
Action Lx
Comment
CAN-bus off
Error 3
All outputs shuts
off.
Check CAN-bus
ADDR-H < 4,9 V
Error 5
-
Check voltage
ADDR-H
ADDR-H > 5,1 V
Error 5
-
Check voltage
ADDR-H
ADDR-L < 0,5 V
Error 5
During start up:
The module turns
off.
Check voltage
ADDR-L
ADDR-L > 4,5 V
Error 5
During start up:
The module turns
off.
Check voltage
ADDR-L
Software error
Error 6
The module turns
off.
Contact supplier.