background image

 15

Connector, C1

7     Installation

Instruction book, IQAN- G3

7

Installation

Connector, C1

Connector pin assignments

Mobile radio antenna (Combi antenna)

Antenna connector

Installing your own SIM card

N

OTICE

The correct PIN code must be set in the IQAN-G3 (using IQANrun) before mounting 
the SIM card. Otherwise, the SIM card could be locked. A 

PIN Unlock Key,

 PUK code 

is required for unlock.

IQANrun configuration not required when using embedded SIM.

Cable kit

Parker no. 20077744

Type

M12-5, 2 m lgth, flying leads

Logical
Symbol

Pin
No.

(I)nput or
(O)utput

Function description 
and/or Signal name(s)

+BAT

2

-

Power supply, positive.

-BAT

1

-

Power supply, negative ground

CAN-H

4

-

CAN high

CAN-L

5

-

CAN low

Antenna kit

Parker no. 20085105

Type

GSM/GPS low profile 
magnetic

Antenna

Parker no. 

Cable 1 (Mobile) FME

1 Signal
2 Ground

Cable 2 (GNSS) SMA

1 Signal
2 Ground

4

1

3

5

2

1

2

1

2

Summary of Contents for IQAN-G3

Page 1: ...IQAN G3 Instruction book Publ no HY33 8415 IB UK Edition 2016 04 22...

Page 2: ...kings Approvals 9 Compliance with FCC 10 5 Product description 11 General 11 System overview 11 Communication 12 CAN 12 GSM UMTS 12 GNSS 12 System Diagnostics 12 SIM Card 12 Antenna 13 6 Mounting 14 M...

Page 3: ...stem start 21 Start the system 21 Appendix A 22 IQAN G3 Technical Overview 22 Absolute Maximum Ratings 22 Environmental ratings 22 Recommended Operating Conditions 23 System 23 Appendix B 24 LED messa...

Page 4: ...nd understood by everyone using the system carrying out service work or making changes to hardware and software The different safety levels used in this manual are defined below WARNING Sections label...

Page 5: ...health care facility observe the restrictions on the use of mobiles Switch the IQAN G3 off if instructed to do so by the guidelines posted in sensitive areas Medical equipment may be sensitive to RF...

Page 6: ...at all times under all conditions Therefore you should never rely solely upon any wireless device for essential communications Remember in order to transmit or receive any type of data the IQAN G3 mu...

Page 7: ...ion see Appendix B on page 24 in this document NOTICE It is required to download the operating system 4 0 or later to enable full functionality of the modem in IQANdesign platform systems NOTICE The I...

Page 8: ...nc tionality Configure the modem in IQANrun if own SIM card is used Account on the Proemion server needs to be registered Activate the modem on the server Built in SIM card needs to be activated on Pr...

Page 9: ...e built in SIM card c Enter the settings from your GPRS internet service provider including the SMSC NOTICE The SMSC must be entered or the modem will not boot properly d Enter SIM PIN code if your SI...

Page 10: ...count at https parker proemion com Create a new account one time with user name and password 4 Activate the modem Before you can start to use the modem you need to activate the modem on your Proemion...

Page 11: ...stics 3 Quick start guide Instruction book IQAN G3 Don t forget to click the Add button after entering modem data NOTICE Modem activation will take maximum of 24 hours office time Forms submitted on F...

Page 12: ...9 What do I need to do to get started with remote diagnostics 4 Markings Approvals Instruction book IQAN G3 4 Markings Approvals...

Page 13: ...interference received including interference that may cause undesired operation Contains transmitter FCC ID XPYLISAU200 FCC Part 15 47 CFR Ch I 2014 07 24 Conducted Emission Limits FCC Part 15 47 CFR...

Page 14: ...are tools The IQAN G3 module System overview The IQAN G3 in a typical system The gateway module IQAN G3 is the remote diagnostic unit in an IQAN system All IQAN G3 devices are equipped with a 3G engin...

Page 15: ...ing GSM 850 900 1800 1900 bands and UMTS HSPA 6 band supporting 800 850 900 1700 1900 2100 MHz bands GNSS The IQAN G3 has GNSS functions Global Navigation Satellite System It supports the satellite na...

Page 16: ...G The antenna should not be mounted in the close environment of fuel tanks vessels with explosives and insufficiently shielded electronic devices It is also not allowed to mount it inside enclosed met...

Page 17: ...n any way Ensure the cabling cannot pull twist or induce sideload on the con nectors Locate the module so that physical impact is avoided Locate the module so that air can circulate to eliminate exces...

Page 18: ...ked A PIN Unlock Key PUK code is required for unlock IQANrun configuration not required when using embedded SIM Cable kit Parker no 20077744 Type M12 5 2 m lgth flying leads Logical Symbol Pin No I np...

Page 19: ...3 enclosure remove the 4 screws holding the enclosure halves together 2 on label surface 2 on the opposite side Carefully pull the enclosure apart Opening the enclosure CAUTION Possibility of electros...

Page 20: ...aster The power supply must be common to both the modem and the master unit to ensure trouble free communication Most importantly the ground connection BAT must be the same NOTICE Do not use the chass...

Page 21: ...N High must match the signals on the CAN terminals of the connected devices IQAN master Connecting IQAN master to IQAN G3 Web portal for activation and modem management NOTICE The IQAN G3 modem must b...

Page 22: ...e the modem on the web portal To register activate the modem use the activation form Access the Activation form For registration you will need to have the modem Serial number IMEI number This will be...

Page 23: ...s about the web portal please contact PROEMION GMBH Donaustr 14 36043 Fulda Germany Contact Germany Phone 49 661 9490 600 Fax 49 661 9490 666 E mail info proemion com PROEMION CORP 711 E Monument Ave...

Page 24: ...na tively the emergency stop may also shut off the diesel engine or a dump valve and with that depressurize the hydraulic system Prepare for system start WARNING Make sure no one is in dangerous proxi...

Page 25: ...lity ISO 11452 2 2004 Radiated susceptibility ISO 7637 2 2004 Conducted transients susceptibility 30 1000MHz 75 100 V 12 V 150 450 V 24 V 20 80 MHz 1 kHz 80 AM 60 mA 80 2000 MHz 1 kHz 80 AM 30 V m Pul...

Page 26: ...ffer from the IQAN G3 rat ings Consult the service provider to determine the temperature rating for the SIM card System TA 25 C unless otherwise specified Parameter Limit values Unit Remark min typ ma...

Page 27: ...o be orange or yellow in modes when the green LED is still lit Off On GPS antenna is ready Malfunction of GPS antenna GSM green On Blink Blink Blink Blink Connected TCP IP active Connecting to a serve...

Page 28: ...25 Dimensioning of the IQAN G3 module Appendix C Instruction book IQAN G3 Appendix C Dimensioning of the IQAN G3 module Unit mm 126 121 42 5 assembly hole 4x 8 5 counterbore 4x 107 109...

Page 29: ...without notice Parker Hannifin Electronic Controls Division SE 435 35 M lnlycke Sweden Tel 46 31 750 44 00 Fax 46 31 750 44 21 www parker com ecd Parker Hannifin Electronic Controls Division 1651 N Ma...

Reviews: