20
IQAN-G2 Technical Overview
Appendix A
Instruction book, IQAN-G2
Recommended Operating Conditions
a
Parameter
Limit values
Unit
Remark
min.
typ.
max.
Recommended operating temperature,
T
ROC
– 30
+70
°C
Voltage supply, V
BAT
9
32
V
a.Recommended operating conditions are given for maximum and minimum conditions where nor-
mal performance is still available from the device. Once the normal operating conditions are exceed-
ed, the performance of the device may suffer.
Also, the operating temperature for the manufactures´s SIM card may differ from the IQAN-G2 rat-
ings. Consult the service provider to determine the temperature rating for the SIM card.
System
T
A
= +25 °C (unless otherwise specified)
Parameter
Limit values
Unit
Remark
min.
typ.
max.
Weight
650
grams
Current consumption, while GSM
transmission in progress
400
200
mA
@14 Vdc
@28 Vdc
Approvals
Parameter
Remark
EU Directives
EN 61000-6-2 (03/2006)
EN 61000-6-3
Immunity standard for industrial environments
Emission standard for residential, commercial,
and light industrial environments
US Standards met
FCC 15/47 CFR Ch 1 (10-01-2010)
FCC 15/47 CFR Ch 1 (10-01-2010)
Conducted emission limits