5.6 Function Parameters
5.6.1 Basic parameters
F100 User’s Password
Setting range: 0
~
9999
Mfr’s value: 8
·When F107=1 with valid password, the user must enter correct user’s password after power on or fault reset
if you intend to change parameters. Otherwise, parameter setting will not be possible, and a prompt “Err1”
will be displayed.
Relating function code: F107 Password valid or not
F108 Setting user’s password
F111 Max Frequency
Setting range: F113
~
590.0Hz
Mfr’s value: 166.6Hz
F112 Min Frequency
Setting range: 0.00Hz
~
F113
Mfr’s value: 0.00Hz
·The max/min frequency can be set according to servo motor.
F113 Target frequency in speed mode
Setting range: F112~F111
Mfr’s value: 1.00
·When servo drive is in the FA30=0 state, the running frequency can be set by F113, which can be adjusted by
up and down key.
F114 Acceleration Time(S)
Setting range:0.001
~
32.00S
Mfr’s value: Subject to model
F115 Deceleration Time (S)
Acceleration Time: The time for servo drive to accelerate to 50Hz from 0Hz
Deceleration Time: The time for servo drive to decelerate to 0Hz from 50Hz
5.6.2 Running control mode
F200 and F201 are the resource of selecting control commands.
Control commands include: starting, stopping, forward running, reverse running, jogging, etc.
”Keypad command” refers to the start/stop commands given by the “Run” or ”stop/reset” key on the keypad.
“Terminal command” refers to the start/stop command given by the “Run” terminal defined by F316-F323.
When F200=2 and F201=2, “keypad command” and “terminal command” are valid at the mean time.
F202 Mode of direction setting
Setting range:
0: Forward running locking;
1: Reverse running locking; 2: Terminal setting
Mfr’s value: 0
The running direction is controlled by this function code together with other speed control mode which can set
the running direction.
F203 Main frequency source X
Setting range:
0: Memory of digital given; 1: External analog AI1;
2: External analog AI2; 6: External analog AI3;
10: MODBUS 11: 485(Mutiple pump combined)
12: CAN communication(Mutiple pump combined)
Mfr’s value: 0
Main frequency source is set by this function code.
0: Memory of digital given
Its initial value is the value of F113. The frequency can be adjusted through the key “up” or “down”, or
through the “up”, “down” terminals.
“Memory of digital given” means after servo drive stops, the target frequency is the running frequency before
F200 Source of start command
Setting range:
0: Keypad command;
1: Terminal command; 2: Keypad
+
Terminal
3: Modbus 4: Keypad
+
T Modbus
Mfr’s value: 2
F201 Source of stop command
Setting range:
0: Keypad command;
1: Terminal command; 2: Keypad
+
Terminal;
3: Modbus 4: Keypad
+
T Modbus
Mfr’s value: 2