Diagnostics
Error
37
6.10.8 Error
Fault code. If COMPAX is in the "Fault" status, the fault code is given a value not equal to 0.
If COMPAX is not in the "Fault" status, this object then gives the value 0.
Object Description
Index
0x603f
Symbol
STOERUNG
Length
2
Min
0x8000
Object code
Variable
Max
0x7FFF
Data type
Unsigned16
Access rights
read
PDO mapping
no
Data Description
Bit
Coding
Bit
Coding
15 ... 12
Main groups
7...0
Details
11...8
Subgroups
Fault codes:
Code
COMPAX error
0000h
E00 Stop/no error
6320h
E01 Not configured
6320h
E02 Limits
1000h
E03
1000h
E04
7300h
E05 MN-Ini not found
1000h
E06
8200h
E07 Processor error
8200h
E08 Synchronous stop is enabled
8200h
E09 Drive not working
8611h
E10 Contour error too large
8600h
E11 Prog. position not reached
7320h
E12 Slip error
7300h
E13 Ini 1 not damped
7300h
E14 Ini 2 not bed.
7320h
E15 Error in the 2. position measuring system
6300h
E16 Record number does not exist
6300h
E17 Record number too large
6300h
E18 Record 250 is assigned
6300h
E19 No room in memory
8612h
E20 Target position behind pos. limit stop
8612h
E21 Target position behind neg. limit stop
8500h
E22 MN is not approached
6200h
E23 Command is not allowed
8400h
E24 Speed is invalid
8600h
E25 Position is invalid
6300h
E26 END command missing for REPEAT
6320h
E27 Parameter cannot be written to
1000h
E28
6320h
E29 Motor values missing
5500h
E30 Hardware fault
6320h
E31 Parameter error
6320h
E32 Parameter error
6300h
E33 Data memory error
6300h
E34 Data memory error
5500h
E35 Hardware fault
5500h
E36 Hardware fault
5111h
E37 Auxiliary v15V missing
5120h
E38 Voltage in the intermediate circuit too high
4210h
E39 Temperature too high
1000h
E40
Code
COMPAX error
5410h
E41 Output stage signals error
7303h
E42 Resolver error
2300h
E43 Output loaded
5111h
E44 Pos. auxiliary voltage outside tolerance
5111h
E45 neg. auxiliary voltage outside tolerance
5112h
E46 24V too large
5112h
E47 24V too small
4310h
E48 Thermostatic switch motor indicates error
7121h
E49 Motor/drive indicates disabling
8612h
E50 Limit switch 1 activated
8612h
E51 Limit switch 2 activated
7200h
E52 Error in emergency stop controlling
7120h
E53 Motor loaded
8400h
E54 Speed too high
8000h
E55 External emergency stop
8000h
E56 Emergency stop directly in COMPAX M
5120h
E57 Voltage in the intermediate circuit too low
4200h
E58 Temperature getting too high
1000h
E59
7200h
E60 Slip warning
1000h
E61
1000h
E62
1000h
E63
1000h
E64
7305h
E65 Encoder module not enabled
1000h
E66
1000h
E67
1000h
E68
1000h
E69
1000h
E70
1000h
E71...E255