Read/Write Example for Sensor’s Broadcast Status Message PGN
Example - Read Configuration Parameter, Message Rate
Identifier
D0
D1
D2
D3
D4
D5
D6
D7
18EFF980
0x81
4
0
FF
FF
FF
FF
FF
DA = 0x80(Speed Sensor)
SA = 0xF9
Command
Type
Configuration
Parameter
Number
Read
Configuration
Reserved Bytes
Example - Response for Read Configuration Parameter, Message Rate
Identifier
D0
D1
D2
D3
D4
D5
D6
D7
18EF80F9
0x81
4
2
0x75
0xFF
0
0
0
DA = 0xF9,
SA = 0x80(Speed Sensor)
Command
Type
Configuration
Parameter
Number
Response
Data
D3(LSB),D4(MSB)
Unused Bytes
Example - Write Configuration Parameter, PGN For Broadcast Messages
Identifier
D0
D1
D2
D3
D4
D5
D6
D7
18EFF980
0x81
4
1
0x75
0xFF
FF
FF
FF
DA = 0x80(Speed Sensor)
SA = 0xF9
Command
Type
Configuration
Parameter
Number
Write
Operation
Data
D3(LSB),D4(MSB)
Reserved Bytes
Read/Write Example for Sensor’s CAN Baud Rate
Example - Read Configuration Parameter, CAN Baud Rate
Identifier
D0
D1
D2
D3
D4
D5
D6
D7
18EFF980
0x81
5
0
FF
FF
FF
FF
FF
DA = 0x80(Speed Sensor)
SA = 0xF9
Command
Type
Configuration
Parameter
Number
Read
Configuration
Reserved Bytes
Example - Response for Read Configuration Parameter, CAN Baud Rate
Identifier
D0
D1
D2
D3
D4
D5
D6
D7
18EF80F9
0x81
0x05
0x02
0x00
0x0
0
0x00
0x00
0x00
DA = 0xF9
SA = 0x80(Speed Sensor)
Command
Type
Configuration
Parameter
Number
Data
Unused Bytes
Example - Write configuration parameter, CAN Baud Rate
(1)
Identifier
D0
D1
D2
D3
D4
D5
D6
D7
18EFF980
0x81
5
1
0
FF
FF
FF
FF
DA = 0x80(Speed Sensor)
SA = 0xF9
Command
Type
Configuration
Parameter
Number
Write
Operation
Data
Reserved Bytes