![Parker Daedal 400LXR Series Product Manual Download Page 37](http://html.mh-extra.com/html/parker/daedal-400lxr-series/daedal-400lxr-series_product-manual_756302037.webp)
404LXR Series Product Manual
Chapter 6 - Maintenance and Lubrication
37
Chapter 6 - Maintenance and Lubrication
Internal Access Procedure
The following procedure outlines the steps required to access the interior of the positioner.
•
Remove carriage end caps by removing four (4) M3 Socket
Head Cap Screws (2pc/carriage side) using a 2.5 mm Allen
wrench.
•
Pull carriage end caps off. Carriage end caps on both sides
of carriage must be removed.
•
Remove the two (2) strip seals clamps by removing four (4)
Phillips Head Screws.
•
Remove strip seal cover plate.