![Parker Compax3S025V2 Operating Instructions Manual Download Page 41](http://html1.mh-extra.com/html/parker/compax3s025v2/compax3s025v2_operating-instructions-manual_3903775041.webp)
Parker EME
Compax3 device description
192-120101 N11 C3I11T11 November 2007
41
Maximum capacity in the axis combination: 2400µF
Connection of a braking resistor on Compax3MP (mains module)
Mimimum line cross section:
1.5mm
2
Maximum line length:
2m
Maximum intermediate circuit
voltage:
810VDC
Switch-on threshold:
780VDC
3.4.7.1
Temperature switch Compax3MP (mains module)
Connector X40 Pin T1R, T2R
Temperature monitoring:
The temperature switch (normally closed contact) must be connected, unless an
error message will be issued.
Temperature switch/relay
No galvanic separation, the temperature sensor (normally closed contact) must
comply with the safe separation according to EN 60664.
If there is no temperature monitoring due to the connected braking resistor, the
T1R and T2R connections must be connected by a jumper.
Without temperature monitoring, the braking resistor might be destroyed.
3.4.8.
Motor / motor brake Compax3M (axis controller)
Connector X43
PIN
Designation
BR+
Motor holding brake *
BR-
Motor holding brake *
PE PE
(motor)
W W
(motor)
V V
(motor)
U U
(motor)
* Please note that Compax3 will report error "open circuit at holding brake"