![Parker Compax3S025V2 Operating Instructions Manual Download Page 243](http://html1.mh-extra.com/html/parker/compax3s025v2/compax3s025v2_operating-instructions-manual_3903775243.webp)
Parker EME
Error
192-120101 N11 C3I11T11 November 2007
243
Standard error reactions:
Reaction 2
: Downramp with "de-energize"
then apply brake
(see page 231) and
finally de-energize.
For errors with standard reaction 2 the
error reaction can be changed
(see page
Reaction 5
: switch-off of the current immediately (without ramp), application of the
brake.
Caution! A Z-axis may drop down due to the brake delay times
Most pending errors can be acknowledged with Quit!
The following errors must be acknowledged with Power on:
0x7381, 0x7382, 0x7391, 0x7392, 0x73A0
Object 550.1 displays error:
value 1 means "no error".
The errors as well as the error history can be viewed in the C3 ServoManager
under optimization (at the top right of the optimization window).
7.1
Error list
Detailed information on the topic of the "error list" can be found in the online help of
the device.