5.2.3.
Configuration of remote modem 2
Settings in Compax3 under "configure communication: Modem settings":
Modem initialization = "ON": After the SSK31 modem cable has been connected,
Compax3 initializes the modem
Modem initialization after Power On = "ON": After Power on of Compax3, the
device initializes the modem
Modem check = "ON": a modem check is performed
The timeout periods are set to reasonable standard values according to our
experience.
Select the modem type: "Westermo TD-33" or "user-defined modem"
For "Westermo TD-33", no further settings are required.
For "user-defined modem", additional settings are only required, if the modem
does not support standard AT commands.
Then you can enter special AT commands.
Note:
When operating the local modem on a telephone system, it may be
necessary to make a blind dialling. Here, the modem does not wait for the
dialling tone. For the Westermo TD33, the additional command sequence is
ATX3.
in the following wizard window, a specific download of the modem configuration
can be made.
Note:
If a configuration download is interrupted, the original settings in the non volatile
memory of the Compax3 are still available.
You have to finish the communication on the PC side and to reset the Compax3 via
the 24V supply before you can start a new trial.
Reinitialization of the remote modem 2
Remove cable on Compax3 X10 and connect again!