Parker EME
Setting up Compax3
192-120101 N11 C3I11T11 November 2007
105
4.2
Test commissioning Compax3
Required wiring:
X4: 24VDC
/3: Enable with 24VDC
X3
Motor / Brake
X1: Mains supply
/1: 230V AC +10%
/2: 0V
/3: PE
X13 to
Motor-Feedback
X12:
(see following)
Inputs/Outputs
X10 to PC
RS232 / RS485
Operational enable of the servo controller:
Plug/Pin
Assignment
X12/6 (no STOP)
= 24V DC (jumper to X12/1)
X12/8 (Energize the motor)
= 24V DC (jumper to X12/1)
X4/3 (Enable power output stage)
= 24V DC (jumper to X4/1)
After you have configured the Compax3 according to your application with the help
of the Compax3 ServoManager, you can now carry out the first motor movements.
In the optimising window of the Compax3 ServoManager you can run the motor in
positive or negative movement direction.
Travel via JOG+ and
JOG-