Technical
Characteristics
Single axis devices
36
192-120102 N16 December 2010
Mains connection Compax3S0xxV2 1AC
Controller type
S025V2
S063V2
Supply voltage
Single phase 230VAC/240VAC
80-253VAC / 50-60Hz
Input current
6Arms
13Arms
Maximum fuse rating per device
(=short circuit rating)
10 A (MCB miniature
circuit breaker, K
characteristic)
16A (automatic circuit
breaker K)
Mains connection Compax3S1xxV2 3AC
Controller type
S100V2
S150V2
Supply voltage
Three phase 3* 230VAC/240VAC
80-253VAC / 50-60Hz
Input current
10Arms
13Arms
Maximum fuse rating per device
(=short circuit rating)
16A
20A
MCB miniature circuit breaker, K characteristic
Mains connection Compax3SxxxV4 3AC
Controller type
S015V4
S038V4
S075V4
S150V4
S300V4
Supply voltage
Three phase 3*400VAC/480VAC
80-528VAC / 50-60Hz
Input current
3Aeff
6Arms
10Arms
16Arms
22Arms
Maximum fuse rating per
device(=short circuit
rating)
6A
10A
16A
20A
25A
MCB miniature circuit breaker, K characteristic
D*
Control voltage 24VDC Compax3S and Compax3H
Controller type
Compax3
Voltage range
21 - 27VDC
Current drain of the device
0.8 A
Total current drain
0.8 A + Total load of the digital o current
for the motor holding brake
Ripple
0.5Vpp
Requirement according to safe extra
low voltage (SELV)
yes
Short-circuit proof
conditional (internally protected with 3.15AT)
Output data Compax3S0xx at 1*230VAC/240VAC
Controller type
S025V2
S063V2
Output voltage
3x 0-240V
3x 0-240V
Nominal output current
2.5Arms
6.3Arms
Pulse current for 5s
5.5Arms
12.6Arms
Power
1kVA
2.5kVA
Switching frequency
16kHz
16kHz
Power loss for In
30W
60W
4. Technical Characteristics