Technical Data
140
I11 T11 192-120101 N6 - March 2004
In this chapter you can read about:
Mains connection: Compax3 S0xx V2
Controller type
S025 V2
S063 V2
Mains voltage
Single phase 10%
80-10% / 50-60Hz
Rated input current
6Aeff
16Aeff
Maximum fuse rating per device
10A (automatic circuit
breaker K)
16 A (automatic circuit
breaker K)
Mains connection Compax3 Sxxx V4
Controller type
S038 V4
S075 V4
S150 V4
S300 V4
Mains voltage
Three-phase 3*400VAC
80-480 VAC+10% / 50-60 Hz
Rated input current
6Aeff
10 Aeff
16Aeff
22Aeff
Maximum fuse rating per
device
10A (automatic
circuit breaker
K)
16 A (automatic circuit
breaker K)
25A (automatic
circuit breaker
K)
Output data: Compax3 S0xx V2
Controller type
S025 V2
S063 V2
Output voltage (at 1*230 V)
3x 0-230V
3x 0-230V
Rated output current (at 1*230 V)
2.5Aeff
6.3Aeff
Pulse current
5Aeff for 5s
12.6Aeff for 5s
Power [hp]
1kVA
2.5kVA
Switching frequency
8kHz
8kHz
Power loss for In [Pv]
30W
60W
Efficiency
95%
96%
The currents are valid for the power output stage clock frequency of 8kHz normally
set.
Output data Compax3 Sxxd V4
Controller type
S038 V4
S075 V4
S150 V4
S300 V4
Output voltage (at 3*400
VAC)
3x 0-400V
Rated output current (at
3*400 VAC)
3.8Aeff
7.5Aeff
15Aeff
30Aeff
Pulse current
(at 400VAC)
7.5Aeff for 5s
15Aeff for 5s
30Aeff for 5s
60Aeff for 5s
9. Technical Data