
Parker EME
Technical Characteristics
192-120100 N16 C3I10T10 - December 2010
213
Output data Compax3S0xx at 1*230VAC/240VAC
Controller type
S025V2
S063V2
Output voltage
3x 0-240V
3x 0-240V
Nominal output current
2.5Arms
6.3Arms
Pulse current for 5s
5.5Arms
12.6Arms
Power
1kVA
2.5kVA
Switching frequency
16kHz
16kHz
Power loss for In
30W
60W
Output data Compax3S1xx at 3*230VAC/240VAC
Controller type
S100V2
S150V2
Output voltage
3x 0-240V
3x 0-240V
Nominal output current
10Arms
15Arms
Pulse current for 5s
20Arms
30Arms
Power
4kVA
6kVA
Switching frequency
16kHz
8kHz
Power loss for In
80W
130W
Output data Compax3Sxxx at 3*400VAC
Controller type
S015V4
S038V4
S075V4
S150V4
S300V4
Output voltage
3x 0-400V
Nominal output current
1.5Arms
3.8Arms
7.5Arms
15Arms
30Arms
Pulse current for 5s
4.5Arms
9.0Arms
15Arms
30Arms
60Arms*
Power
1kVA
2.5kVA
5kVA
10kVA
20kVA
Switching frequency
16kHz
16kHz
16kHz
8kHz
8kHz
Power loss for In
60W
80W
120W
160W
350W
* With cyclic peak currents (S8 or S9 operation), the device utilization (683.2) may
not be > 70%; otherwise it is necessary to use a condenser module “
C4Module
(see on page 201
Output data Compax3Sxxx at 3*480VAC
Controller type
S015V4
S038V4
S075V4
S150V4
S300V4
Output voltage
3x 0-480V
Nominal output current
1.5Arms
3.8Arms
6.5Arms
13.9Arms
30Arms
Pulse current for 5s
4.5Arms
7.5Arms
15Arms
30Arms
60Arms*
Power
1.25kVA
3.1kVA
6.2kVA
11.5kVA
25kVA
Switching frequency
16kHz
16kHz
16kHz
8kHz
8kHz
Power loss for In
60W
80W
120W
160W
350W
* With cyclic peak currents (S8 or S9 operation), the device utilization (683.2) may
not be > 70%; otherwise it is necessary to use a condenser module “
C4Module
(see on page 201