Introduction
Hydraulics controller
12
192-121100 N6 June 2008
2.6
Conditions of utilization for CE-conform operation
- Industry and trade -
The EC guidelines for electromagnetic compatibility 2006/95/EC and for electrical
operating devices for utilization within certain voltage limits 2004/108/EC are
fulfilled when the following boundary conditions are observed:
Operation of the devices only in the condition in which they were delivered,
i.e. with all housing panels.
Shielding connection of the valve cables
The cable should be fully screened and connected to the Compax3 housing. We
offer a special Shield connecting terminal as accessory item (ZBH./...).
The shield of the valve cable must also be connected with the valve housing. The
fixing (via plug or screw in the terminal box) depends on the valve type.
<100m
Use only with aligned controller (to avoid control loop oscillation).
Signal lines and power lines should be installed as far apart as possible.
Signal leads should never pass close to excessive sources of interference (motors,
transformers, contactors etc.).
Make sure to use only the accessories recommended by Parker
Connect all cable shields at both ends, ensuring large contact areas!
This is a product in the restricted sales distribution class according to EN
61000-6-4. In a domestic area this product can cause radio frequency
disturbance, in which case the user may be required to implement
appropriate remedial measures.
Requirements for
encoder cable
Compax3:
Control:
Cable installation:
Accessories:
Warning: