The ACR-View software is a user-friendly interface for verifying status of and
commanding the ACR EPL controller and the EPL network it manages. Use
ACR-View to perform additional troubleshooting of your network and drive.
Refer to the ACR EPL controller user’s guide for details of using the ACR-
View software.
Once you have established an EPL connection as indicated by the Aries EPL
drive EPL Status LED, launch ACR-View on the computer system connected
to your EPL network.
1. Open the Configuration Wizard. Select Axes, then select the desired
axis (drive/CN).
2. Set the drive motor combination used, then check the box next to “I
want to edit the mechanical/electrical parameters for my motor
(Advanced).”
3. Click Next and verify that the motor parameters are correct.
4. Continue through the configuration wizard and verify that all the
parameters for the axis are correct.
Terminal Emulator (Hyper Terminal)
A terminal emulator such as Hyper Terminal will allow basic access to the
drive’s native commands. This may be connected directly to the drive via a
standard Ethernet port, using TCP/IP and the IP address of the drive. The
drive IP address is 192.168.100.xx, where xx is the front panel switch setting.
The terminal emulator may also connect to the drive through the ACR EPL
controller while EPL is running. After the terminal emulator is connected to
and communicating with the ACR9030 or ACR9040 via an available
communications port, the following command sequence is an example of
how that connection can be extended to the drive.
OPEN “EPLD0:” AS #1
(open a connection to the drive)
TALKTO #1
(invoke
the
TALKTO
function)
At this point the terminal emulator should be communicating directly with the
drive, and all native drive commands should function. For example, the
following command should elicit a response:
TDTEMP
(drive temperature query)
26.000
(drive will respond with the temperature)
To disconnect use the following sequence:
<ESC>
(escape key, to exit from
TALKTO
function)
CLOSE #1
(close the connection to the drive)
Motor Control
The first step in troubleshooting motor-control issues is to examine the drive
status LEDs. Use Table 83 to determine the condition they indicate. Use the
additional information in this section to take corrective action.