COMMUNICATIONS
50
ACR7000 Controller Installation Guide
9
Click the radio button next to
Use the following IP address
10
Enter an IP address with the same first three octets as the default ACR7000 IP address (192.168.100).
The last octet of the ACR7000 is by default “1”. Select a different number for the PC in the valid range is
1 to 254. Using 000 or 255 is not valid. In the example the IP address is set to 192.168.100.222. Set the
Subnet mask value to 255.255.255.0. Your window should look like the following:
Figure 7. -
Internet Protocol Properties Screen Completed
11
Click
OK
. It is now safe to close these windows.
IMPORTANT: It is good practice to isolate the ACR7000 and related devices on their
own subnet so that their performance is not affected by high volume
network traffic.
Verifying the IP Address
The following verifies the Ethernet is set up correctly.
1
In Parker Motion Manager, the IP Address box is the value for the controller.
2
In the dialog box, click
Connect
.
3
In the Terminal Emulator, type VER. If the Ethernet is set up correctly, the terminal emulator reports the
firmware version information for the ACR7000 Controller.
Summary of Contents for ACR7000 Series
Page 1: ...Effective September 2020 Document Number 88 033593 01A User Guide ACR7000 Controller...
Page 9: ...INTRODUCTION ACR7000 Controller Installation Guide 9 CHAPTER 1 Introduction...
Page 43: ......
Page 44: ...COMMUNICATIONS 44 ACR7000 Controller Installation Guide CHAPTER 4 Communications...
Page 51: ......
Page 52: ...BASIC OPERATION 52 ACR7000 Controller Installation Guide CHAPTER 5 Basic Operation...
Page 58: ...APPENDIX A 58 ACR7000 Controller Installation Guide Appendix A Accessories...