ACR2000 Hardware Manual
P/N PM08117
14
ACR2000 MOTHERBOARD JUMPERS
Battery Back-Up Select Jumpers (J10 and J11)
These two jumpers allow for disabling and enabling of the battery back-up when a
ACRCOMM communications module is present.
When an ACRCOMM module is present and the jumpers are set to “Battery Function
Enabled”, user programs on the board are retained when power is removed. When an
ACRCOMM module is present and the jumpers are set to “Battery Function Disabled”,
user programs on the board are not retained when power is removed.
When no ACRCOMM module is present, the jumpers must be set to “Battery Function
Disabled” position for ACR2000 to function.
Battery Back-up Jumpers
Battery Function
J10
J11
Battery Function Disabled
1-2
1-2
Battery Function Enabled
2-3
2-3
Table 1.7 ACR2000 Battery Back-Up Enable Jumpers
Refer to Figure 1 for jumper location.
Summary of Contents for ACR2000
Page 1: ...Automation p n YPM08117 ACR2000 Hardware Manual Effective October 7 2002...
Page 2: ...This page intentionally left blank...
Page 6: ...This page intentionally left blank...
Page 12: ...ACR2000 Hardware Manual P N PM08117 2 This page intentionally left blank...
Page 13: ...Chapter 1 ACR2000 Motherboard Hardware Set Up 3 CHAPTER 1 ACR2000 MOTHERBOARD HARDWARE SETUP...
Page 33: ...Chapter 2 ACRCOMM Module Hardware Set Up 23 CHAPTER 2 ACRCOMM MODULE HARDWARE SETUP OPTIONAL...
Page 45: ...Chapter 3 ACR2000 Specification 35 CHAPTER 3 SPECIFICATIONS...
Page 48: ...ACR2000 Hardware Manual P N PM08117 38 This page intentionally left blank...
Page 49: ...Chapter 4 ACR2000 Mechanical Drawings 39 CHAPTER 4 ACR2000 MECHANICAL DRAWINGS...