Humidity Setting

• Tap the Humidity Button to set the humidity level from 40% to 80% in 5% increments, the set 

humidity level will flash three times to confirm your setting.

• When the preset humidity level is reached, the unit will stop misting. 
• To cancel Humidity setting, tap and hold the Humidity Button for 2 seconds or repeatedly tap the 

Humidity Button until “--” is displayed.

The most comfortable environmental humidity is between 40%-60%. Please adjust the mist as 
needed.

Warm Mist Adjustment

• Tap the Warm Mist Button to cycle through High (level 3) -> Medium (level 2) -> Low (level 1) heat 

levels -> OFF. The corresponding heat level will light up on the LED Display.

• The set heat level will flash three times to confirm your setting.

AUTO Mode

• Tap the AUTO button to activate the automatic humidifying mode.
• Under AUTO mode, the mist level and heat level are automatically adjusted based on the environ-

mental humidity to the most comfortable level (55%~65%).

• Once 65% humidity is reached, the humidifier will shut off automatically. When the environmental 

humidity is below 60%, the unit will restart working again.

• When AUTO mode is activated, changing the mist level or heat level will cancel the AUTO mode. 

Sleep Mode

• Tap and hold the AUTO Button on the control panel for 2 seconds or directly press the Sleep Button 

on the remote control to turn off the LED display with a beep.

• To turn the display back on, tap any button on the control panel to wake it up. If no operation is 

done within 3 seconds, the LED display will turn off automatically.

12

11

• When Low Water Protection is activated under sleep mode, the LED display will flash 3 times 

without beeps. Tap and hold the AUTO Button for 2 seconds again to turn off the LED display with a 
beep.

Timer Setting

• Tap the Timer Button to set the timer from 1 to 9 hours by 1 hour increments, the timer will flash 

three times to confirm your setting. When time is up, the unit will automatically turn off.

• To cancel Timer setting, 

1. Keep tapping the Timer button until “0H” displayed or 
2. Tap and hold the Timer Button for 2 seconds.

Low Water Protection

• When there is not enough water inside the water reservoir, the humidifier will stop misting and Low 

Water Protection will be activated. The LED display will flash 3 times with 3 beeps. It is designed for 
safety to prevent the humidifier from possibly overheating and damaging the atomizer. 

• The humidifier cannot be started under low water status.

Memory Function

If power is not disconnected, the humidifier will always remember your last settings (except timer 
setting) once you turn it on again.

Summary of Contents for PE-AH009

Page 1: ...HYBRID ULTRASONIC HUMIDIFIER User Manual PE AH009 Questions or Concerns support parisrhone co...

Page 2: ...y Setting Warm Mist Adjustment AUTO Mode Sleep Mode Timer Setting Low Water Protection Memory Function CONTENTS 01 01 06 08 10 07 06 02 03 04 05 08 08 10 11 11 12 12 11 11 12 09 09 10 10 CLEANING AND...

Page 3: ...1 2 01 Thanks for choosing Paris Rh ne Ultrasonic Cool Mist Humidifier This product is covered with Paris Rh ne product and labor warranty for 12 months from the date of its original purchase The war...

Page 4: ...your hand or any other object to cover the nozzle while the unit is on to avoid damaging the product or causing injury 1 DO NOT clean the unit while it is connected to a power source or while it is o...

Page 5: ...djust any electrical or mechanical functions on this humidifier Doing so will void your warranty 1 x Paris Rh ne Top Fill Hybrid Ultrasonic Humidifier 1 x Remote Control 1 x Cleaning Brush 3 x Mineral...

Page 6: ...TIONS AND FUNCTIONS 1 2 3 Add Water 1 Remove the tank cover 2 Fill the tank with filtered or purified water 3 Place the tank cover back PRODUCT DIAGRAM 08 07 1 2 6 11 3 4 5 7 8 9 10 12 13 14 Add Essen...

Page 7: ...set mist level 2 3 1 while setting Shows the set humidity level 40 80 RH while setting Shows the set time 0 9H while setting Power On Off Tap the Power Button once to turn the humidifier ON with defa...

Page 8: ...Sleep Mode Tap and hold the AUTO Button on the control panel for 2 seconds or directly press the Sleep Button on the remote control to turn off the LED display with a beep To turn the display back on...

Page 9: ...gh the air outlet air inlet or the control buttons and LED display 3 DO NOT wash any part of this humidifier in dish washer which will damage the humidifier and void the warranty Daily Maintenance Tur...

Page 10: ...ervoir or tank 3 Pack the unit safely and store in a cool dry location 16 15 Note It is recommended to change the absorption pad every 2 4 weeks depending on water hardness Cleaning the Aroma Pad 1 To...

Page 11: ...than the preset humidity reset to a higher level Mineral buildup on the atomizer Clean the atomizer as instructed Problem Possible Causes Solution Mist height is low damping surrounding desk or floor...

Page 12: ...rovide after sales service for products that are sold by Paris Rh ne or Paris Rh ne authorized retailers and distributors If you have purchased your appliance from a different place please contact you...

Page 13: ......

Page 14: ...Rev_1 1_EN support parisrhone co Manufacturer Shenzhen NearbyExpress Technology Development Co Ltd Address Floor 7 Building E Galaxy World Phase II Shenzhen China www parisrhone co Made In China...

Page 15: ...150 200mm 128 80...

Reviews: