SafeAir
™
M-350 Pro Installation Guide
12
https://parazero.com/
5.3
Flight Preparations
1
The SAP should be charged using the provided USB-C cable for at least three hours prior
to the first flight, using a USB power supply. Because the SAP
interfaces with the drone’s
power supply via FTS connectivity, the system is automatically charged during flight,
resulting in limitless SafeAir battery operation. If the system is not used often, it should be
charged before flight for three hours.
Charge the SAP when the safety pin is all the way in.
2
(Optional) Charge the RC using the provided USB cable, using a USB power supply, for at
least one hour before first use. Charging should be made while the RC is turned off.
Caution
When the RC is turned off or there is no link between the RC and the receiver, manual
triggering is not available
3
Using the desktop application allows for firmware updates, automatic download of flight
logs, and system configuration. Disconnect the FTS cable and the parachute cable from
the SAP, remove the safety pin completely, and connect the SAP to your computer using
the provided USB-C cable. The desktop application installation and operational
instructions may be found
. Use the pyro-dummy connected instead of the
parachute cable for the SAP during initialization process.
Warning
Please disconnect FTS and parachute cables from the SmartAir to prevent inadvertent
activation during the firmware update process
4
Perform the self-test assessment found