8
The Clear O3® should run with the filter pump
as the filter pump creates the air draw through
the unit needed to create ozone. Do not set
the Clear O3® to run when the filter pump is
off and not pulling air through the unit.
5. Use external ground lug to connect the
Clear O3® to the pool pump ground bond.
(Fig. 5B)
6. Turn on power to filtration system pump.
Check glow tube on the left front of
the Clear O3®. A light blue light indicates lamp is lit and the unit should be
producing ozone. (Fig. 9)
WARNING:
UV light produced by this unit is harmful to the eyes and may cause
blindness! Do not look directly at a lit bulb!
Fig. 9
Light Blue Glow Tube
When a pool is built without a controller or time clock for the pump and a variable speed
pump is used the power input is hot all the time. The variable speed pump is turned on and
off by its own internal controller. There is nothing to connect the ClearO3 to (a relay in a
control panel) so it will turn on and off with the pump. When the ClearO3 is installed on these
pools it does not have a way to be turned off when the pump is not operating. These pumps
are available from all the major pool equipment suppliers and several small manufacturers.
Paramount has available an add-on paddle flow switch (Paramount part# 004-402-0010-00
or Grid Controls part # 57-F1-225-00W). The power is run through this switch and then to
the ClearO3. The flow switch is plumbed in the main line of the pool return. When it sees
flow the ClearO3 is turned on.
ALTERNATE ELECTRICAL CONNECTION FOR MULTI-SPEED
PUMP WITHOUT A CONTROLLER OF TIME CLOCK
Fig. 10
breaker panel
Clear03
steel tight flex
conduit
flow switch