6
Fig. 4
120 Vac 50-60 Hz 0.8A
230 Vac 50-60 Hz 0.38A
OUTPUT
30-60 Vac 700mA - 800mA CLASS P, TYPE
1, RATING: A “RS” ELECTRONIC BALLAST
BLACK
WHITE
WHITE
WIRE NUTS
GREEN
BLACK
BLACK
WHITE
YELLOW WITH
GREEN STRIPE
2X BLUE
2X RED
LAMP
LT GREEN
LT GREEN
WARNING:
Turn off power at main source before making any
electrical connections or servicing the unit.
1. A licensed electrician should make all electrical connections. Make sure the
unit is grounded by connecting to the pool equipments bond wire to comply
with local electrical codes.
2. Turn off power to the filtration system pump at the circuit breaker.
3. Install an approved seal tight flex conduit (not included) rated for outdoor
use, between the ClearO3 unit and filtration system pump time clock. Feed
the free ends of the wires from the ClearO3 through the conduit and into the
filter system pump time clock or equipment panel (Fig. 5A & 5B). Time clock
or equipment panel must be suitable for field wiring. Electrical connections
should be made in the time clock or equipment panel. NO ELECTRICAL
CONNECTIONS ARE TO BE MADE INSIDE THE CLEARO3!
3.1. The wires from the ClearO3 unit are provided to facilitate connecting to
a panel board that is a maximum of 10 feet away from the unit. If longer
conduit length is needed, then a Listed junction box suitable for the
application may need to be added. All electrical connections need to
be made in accordance with the National Electrical Code.
INTERNAL WIRING DIAGRAM OF THE CLEARO3
UNIT. NOT TO BE USED FOR INSTALLATION.
MAKING ELECTRICAL CONNECTIONS