10.

 

Hardware Specification 

 

ETHERNET 

 

 

Standards   

IEEE 802.3 Ethernet 

   

IEEE 802.3u Fast Ethernet 

   

IEEE 802.3ab Gigabit Ethernet 

   

IEEE 802.3af Power over Ethernet 

   

IEEE 802.3at Powe over Ethernet Plus 

Forwarding and Filtering Rate   

14,880pps (10Mbps) 

   

148,800pps (100Mbps) 

   

1,488,000pps (1000Mbps) 

Packet Buffer   

1Mbits 

Packet Length   

10KB 

MAC Address Table   

8K 

Exchange Property   

Backplane Bandwidth 20Gbps 

   

Packet Forwarding Rate 14.88Mbps 

INTERFACE 

 

 

Wired   

4 x 10/100/1000 BASE-T RJ45 PoE+ 

   

1 x 10/100/1000 BASE-T Uplink 

Fiber   

1 x 1000 BASE-FX SFP 

PoE 

 

 

Standard   

IEEE 802.3af/ IEEE 802.3at 

Port Type   

RJ45 

Power Pin Assignment   

4/5 (+) 7/8 (-) 

Power Budget   

Max Combined 100W 

ENVIRONMENTAL 

 

 

Operating Temperature   

-40°C to +80°C 

Storage Temperature   

-40°C to +85°C 

Relative Humidity   

5% - 95% non-condensing 

MTBF   

>200,000 hours 

ELECTRICAL 

 

 

Operating Voltage   

12-48VDC (Terminal Block Connector) 

Power Consumption   

5W without PoE 

 105W with Max PoE 

Short-Circuit Protection   

Auto-Reset 

Reverse Polarity   

Protected 

MECHANICAL 

 

 

Dimensions   

145mm x 145mm x 40mm 

Weight   

800g 

Casing   

Aluminium 

Mounting   

DIN Rail & Wall Mount 

INDICATORS 

 

 

PWR   

Power Status 

L/A   

Link Activity 

PoE   

PoE Status 

SPD   

Link Speed 

Fuse   

Fuse Fail 

High   

High Input Voltage Warning 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for PDT-NSU-7105-MP-SF-I

Page 1: ...Operations Manual PDT NSU 7105 MP SF I Revision 1 0 March 2023...

Page 2: ...6 Connectors and Indicators 6 6 1 LED Indicators 6 6 2 Fuse Holder 6 6 3 RJ45 Ports 7 6 4 Power Connections 7 6 5 PoE Output 7 6 6 PoE Budget 7 7 Installation Procedures 8 7 1 DIN Rail Installation 8...

Page 3: ...1 Revision History Date Rev By Comments Checked Date 14 03 2023 01 JF Initial Release SC 14 03 2023...

Page 4: ...ption AP Access Point CCA Copper Clad Aluminium DC Direct Current IEEE Institute of Electrical and Electronic Engineers IP Internet Protocol MTBF Mean Time Between Failures PD Power Device PoE Power o...

Page 5: ...arty To prevent possible danger damage and bodily harm when handling the equipment please observe all warnings cautions notices contained in this section Failure to heed the following danger warnings...

Page 6: ...0 BASE T Port and 1 x 100 1000 BASE X auto detecting SFP Port to allow connectivity using 1 or 2 core Single or Multi Mode fiber The unit is designed for harsh industrial conditions and environments a...

Page 7: ...No Connection OFF PoE Established L A Link Activity Yellow OFF Not Running Flashing Running SPD Port Speed Yellow OFF No Connection ON 1000Mbps SFP SFP Module Green OFF Not Detected ON Connected FUSE...

Page 8: ...es using 1 or 2 core fiber in Single or Multi Mode fiber configuration 6 4 Power Connections Model V V Power Input PDT NSU 71045 MP SF I GND 12 48VDC Note All Power Supplies should provide over curren...

Page 9: ...e switch to the required surface using appropriate fixings 7 Installation Procedures 7 1 DIN Rail Installation 7 2 Wall Mount Installation Attach the DIN Rail Bracket if not fitted to the switch case...

Page 10: ...ports TP1 4 are available for other devices or connections All cables should be solid copper and not CCA 8 3 SFP Port Connections Ensure that the SFP socket is clear from any dirt or contamination an...

Page 11: ...9 Physical Dimensions...

Page 12: ...Uplink Fiber 1 x 1000 BASE FX SFP PoE Standard IEEE 802 3af IEEE 802 3at Port Type RJ45 Power Pin Assignment 4 5 7 8 Power Budget Max Combined 100W ENVIRONMENTAL Operating Temperature 40 C to 80 C St...

Page 13: ...tic Discharge EN 61000 4 2 2009 Electromagnetic Field Immunity EN 61000 4 3 2010 Electrical Fast Transients EN 61000 4 4 2012 Surge EN 61000 4 5 2014 A1 2017 Conducted Immunity EN 61000 4 6 2014 Power...

Reviews: