Abbreviation 

Description 

AP 

Access Point 

CCA 

Copper Clad Aluminium 

DC 

Direct Current 

IEEE 

Institute of Electrical and Electronic Engineers 

IP 

Internet Protocol 

MTBF 

Mean Time Between Failures 

PD 

Power Device 

PoE 

Power over Ethernet 

PSU 

Power Supply Unit 

 

 

 

 

Summary of Contents for PDT-NSU-7102-MP-SF-I

Page 1: ...Operations Manual PDT NSU 7102 MP SF I Revision 2 0 March 2023...

Page 2: ...erview 5 6 Connectors and Indicators 6 6 1 LED Indicators 6 6 2 RJ45 Ports 7 6 3 Power Connections 7 6 4 PoE Output 7 6 5 PoE Budget 7 7 Installation Procedures 8 7 1 DIN Rail Installation 8 7 2 Wall...

Page 3: ...1 Revision History Date Rev By Comments Checked Date 09 03 2023 01 JF Initial Release SC 10 03 2023...

Page 4: ...ption AP Access Point CCA Copper Clad Aluminium DC Direct Current IEEE Institute of Electrical and Electronic Engineers IP Internet Protocol MTBF Mean Time Between Failures PD Power Device PoE Power o...

Page 5: ...arty To prevent possible danger damage and bodily harm when handling the equipment please observe all warnings cautions notices contained in this section Failure to heed the following danger warnings...

Page 6: ...supporting 2 x 10 100 1000 BASE T RJ45 Ports and 1 x 100 1000 BASE FX SFP Ports with the 2 x RJ45 Ports being PoE capable 802 3at This model can operate on input voltages from 12 48VDC and the device...

Page 7: ...ns as indicated in the table below LED Name Colour State Status PWR Power Source Green OFF Power Not Avail ON Power Available FX Fiber Link Green ON SFP Connected OFF SFP Not Connected NC N A Green N...

Page 8: ...aining SFP port is 100 1000 BASE FX and accept a wide range of SFP modules 6 3 Power Connections Model V V Power Input PDT NSU 7102 MP SF I GND 12 48VDC Note All Power Supplies should provide over cur...

Page 9: ...e switch to the required surface using appropriate fixings 7 Installation Procedures 7 1 DIN Rail Installation 7 2 Wall Mount Installation Attach the DIN Rail Bracket if not fitted to the switch case...

Page 10: ...ports TP1 4 are available for other devices or connections All cables should be solid copper and not CCA 8 3 SFP Port Connections Ensure that the SFP socket is clear from any dirt or contamination an...

Page 11: ...9 Physical Dimensions...

Page 12: ...ERFACE Wired 2 x 10 100 BASE T RJ45 Fiber 1 x 1000 BASE FX SFP PoE Standard IEEE 802 3af IEEE 802 3at Port Type RJ45 Power Pin Assignment 4 5 7 8 Power Budget 48VDC Supply 120W 24VDC Supply 90W 12VDC...

Page 13: ...tic Discharge EN 61000 4 2 2009 Electromagnetic Field Immunity EN 61000 4 3 2010 Electrical Fast Transients EN 61000 4 4 2012 Surge EN 61000 4 5 2014 A1 2017 Conducted Immunity EN 61000 4 6 2014 Power...