Users Instruction
SECTION FIVE
The only user removable parts are: -
•
Cast fret
•
Loose fuel bed components
•
Decorative effect trim
jInstallation Instructionsl
SECTION SIX • ••
Category of appl
i
ance:
B
IIAS
Category
1
2H
Overall dimensions:_
Height
605mm (or 555mm for the Low
version)
.
Width
505mm
Forward Projection:
.
?5mm, (From fireplace opening including fret
.
)
Weight
11kg (Boxed excluding fret)
9.5kg (Unboxed excluding fret)
Gas Type:
G20 Natural Gas
Gas Pressure:
20 mbar +/- 1.0mbar
Pressure Test Point Location
:
Gas inlet elbow
Gas Input (Gross):
.
?0 kW (Maximum)
4
.
4 kW (Minimum)
Injector:
Marked 460
Gas Connection
:
8.0mm 0/0
,
tube.
Data Badge Location:
Behind decorative trim
PACK CONTENTS
•
Appliance
•
Owners Instruction
•
Foam Seal
•
Trim
Refractory Fuel Bed Components
•
Rear Matrix
•
Front Matrix
•
Loose Coals - 13 coal
'
A' (Long)
10 coal 'B
'
(Triangle
)
•
or Loose Pebbles - 14 Large
,
2 Smal
l
&
2 Half
SECTION SEVEN • - •
•
THIS APPLIANCE
MUST ONLY BE INSTALLED IN GREAT BRITAIN OR IRELAND.
•
THE APPLIANCE
IS SUITABLE FOR USE ON NATURAL GAS ONLY.
•
THE APPLIANCE
IS INTENDED FOR DECORATIVE PURPOSES.
•
(GB) NO SPECIAL VENTILATION
BRICKS OR VENTS ARE REQUIRED INTO THE ROOM
CONTAINING
THE
APPLIANCE,
PROVIDING
NORMAL
ADVENTITIOUS
ROOM
VENTILATION
EXISTS. THE INSTALLER
MUST SATISFY THIS POINT BY CARRYING
OUT
THE MANDATORY
SPILLAGE TEST.
(lE) PERMANENT
VENTILATION
MUST COMPLY WITH THE REGULATIONS
CURRENTLY
IN FORCE.