Paragon DRG-1800 User Manual Download Page 1

User Manual

 DRG-����、DRG-���� distribution 

frequency isolation safety barriers

Before using this device, please read the instructions carefully and keep them properly for reference and reference. The color and appearance 

may vary depending on the product. If the specifications are changed in the future for the purpose of improving performance, no further 

notice will be given.

Accessory

�. Please check if all items are included in your product. 

If there is any loss, please contact your sales personnel.

�. The color and shape of the object may vary depending 

on the model.

�. The number of baffles provided may vary depending 

on the quantity of products purchased.

Handbook

Others

Safety Barrier User 

Manual X�

Blocking (depending 

on the quantity of 

products purchased)

Used to protect base terminals, a

group of fiveisolators.

To add, please contact the sales 

staff to purchase separately.

Warning!

�. Read this manual carefully before installation and use; If in doubt, please contact us.

�. It is strictly prohibited to disassemble and install the instrument without permission to prevent instrument failure or failure.

�. The product shell holes are designed to provide the necessary heat dissipation, in order to ensure the  reliable operation of the 

product and prevent it from overheating, do not plug or cover these holes. 

�. The surrounding environment must not have strong vibration, shock and large current and spark electromagnetic induction.

�. The air should not contain chromium, nickel, silver coating corrosion effect of the medium, should not contain flammable, 

explosive substances.

�. Do not insert any metal objects into the hole of this product, otherwise it will cause short circuit.

�. For products with base, the exposed part of base terminal should be inserted with our matching block.

�. If the operation of this product is abnormal, especially if any unusual odor is emitted, please remove this product immediately and 

contact the company.

Product description

The frequency isolation safety barrier achieves the safe 

transmission of frequency signals generated by hazardous area 

instruments to the safe area output. The input adopts a hysteresis 

comparison circuit with high anti-interference performance, while 

providing power to on-site instruments. This product requires 

independent power supply, with power, input, and output isolated.

Technical parameter

Warranty Description

�. The products have undergone strict inspection and quality 

control before leaving the factory. If any abnormalities are 

found or internal modules are suspected to be faulty, please 

contact PARAGON in a timely manner;

�. Within five years from the date of shipment, any quality issues

that arise during normal use of the product will be repaired free 

of charge by PARAGON.

�. Product damage caused by human factors or natural disasters 

is not within the scope of repair.

The isolation type safety barrier and the on-site intrinsic safety 

instrument are connected to form an intrinsic safety explosion-proof 

circuit (intrinsic safety circuit). The system must confirm before use:

�. The explosion-proof level of on-site intrinsically safe instruments 

should comply with the operating environment, and they should be 

certified by a nationally authorized explosion-proof product certification 

agency and have obtained an explosion-proof qualification certificate.

�. The certification parameters between the isolated safety barrier 

and the on-site intrinsic safety instrument are clear and comply 

with GB/T����.��, ���.�, etc.

�. If there are unclear parameters, it is necessary to form an intrinsically 

safe circuit system and obtain explosion-proof products authorized by 

the state confirmation from the certification body.

Intrinsically safe explosion-proof circuit system

National Quality Inspection and Testing Center for Explosion proof 

Electrical Products (CQST)

Explosion proof sign: [Exia Ga] IIC

Certification number: CNEx��.����

Intrinsic safety parameter: Um=���VAC/DC

DRG-����(�-��)、DRG-����(�-��)

Uo=��VDC,lo=��mA,Po=���mW,Co=�.��μF,Lo=�.�mH

DRG-����(�-�)、DRG-����(�-�)

Uo=��.�VDC,lo=��mA,Po=���mW,Co=�.��μF,Lo=�.�mH

Safety and explosion-proof certification

【Product Features】: IC explosion-proof grade, wide range power

 supply, in compliance with EMC standards

【Installation site】: The surrounding air should be free of corrosive 

media that can corrode chromium, nickel, and silver coatings

【Applicable to site and equipment】: Installed in a safe place, it can 

communicate with Zone � frequency equipment with IIA, IIB, and IIC 

hazardous gases

【Overall dimensions】: 

Base power supply: Width ��� × Height ��� × Depth��� (mm)

Terminal power supply: Width ��.� × Height ��� × Depth ��� (mm)

【Overall weight】: ���g

Structure and overall dimensions

【Number of Channels】: DRG-���� one in one out

                                                 DRG-���� one in two out

【Power supply voltage】: ��-��VDC

【Safety side input】: 

             Maximum distribution voltage for hazardous area 

instruments: ��V optional

             Minimum distribution voltage: �.�V (output ��mA)

             Signal level: high level ≥ �V, low level ≤ �V

             Frequency ≤ ��kHz, amplitude ≤ ��V, duty cycle ≥ ��%

【Dangerous side output】: 

                                 Signal level: Low level ≤ �.�V, high level ≥ �.�V

                                 Drive current: ≤ ��mA

                                 Load resistance: ≥ �K Ω
      

【Electromagnetic compatibility】: 

                 In accordance with GB/T ����� (IEC �����-�)

【Insulation strength】: 

                 ����VAC/min between intrinsic safety end and non intrinsic 

safety end

                 ����VAC/min between non intrinsically safe terminals

【Output accuracy】: �.�% F.S

【Temperature drift】:�.��% F.S./C

【Power protection】: Power reverse protection

【Working temperature】: -�� ° C~+�� ° C

【Relative humidity】: ��% to ��% RH

【Storage temperature】: -�� ℃~+�� ℃

【Product Structure】: ��mm rail clamp type, PC+ABS flame-retardant 

housing material, plug-in terminal

Performance index

Address: ��th to ��th floors, Building �, No. ��Dongcun Road, 

Jiangning District, Nanjing City

Central:���-��������/����

Website: http://www.cn-paragon.com

Technical support:�����������

E-mail: [email protected]

Using Tutorials WeChat official account

Nanjing Paragon Technology Co.,LTD

Reviews: