Handbook
Others
Safety Barrier User
Manual X�
Blocking (depending
on the quantity of
products purchased)
Used to protect base terminals, a
group of fiveisolators.
To add, please contact the sales
staff to purchase separately.
Warning!
�. Read this manual carefully before installation and use; If in doubt, please contact us.
�. It is strictly prohibited to disassemble and install the instrument without permission to prevent instrument failure or failure.
�. The product shell holes are designed to provide the necessary heat dissipation, in order to ensure the reliable operation of the
product and prevent it from overheating, do not plug or cover these holes.
�. The surrounding environment must not have strong vibration, shock and large current and spark electromagnetic induction.
�. The air should not contain chromium, nickel, silver coating corrosion effect of the medium, should not contain flammable,
explosive substances.
�. Do not insert any metal objects into the hole of this product, otherwise it will cause short circuit.
�. For products with base, the exposed part of base terminal should be inserted with our matching block.
�. If the operation of this product is abnormal, especially if any unusual odor is emitted, please remove this product immediately and
contact the company.
Product description
The frequency isolation safety barrier achieves the safe
transmission of frequency signals generated by hazardous area
instruments to the safe area output. The input adopts a hysteresis
comparison circuit with high anti-interference performance, while
providing power to on-site instruments. This product requires
independent power supply, with power, input, and output isolated.
Technical parameter
Warranty Description
�. The products have undergone strict inspection and quality
control before leaving the factory. If any abnormalities are
found or internal modules are suspected to be faulty, please
contact PARAGON in a timely manner;
�. Within five years from the date of shipment, any quality issues
that arise during normal use of the product will be repaired free
of charge by PARAGON.
�. Product damage caused by human factors or natural disasters
is not within the scope of repair.
The isolation type safety barrier and the on-site intrinsic safety
instrument are connected to form an intrinsic safety explosion-proof
circuit (intrinsic safety circuit). The system must confirm before use:
�. The explosion-proof level of on-site intrinsically safe instruments
should comply with the operating environment, and they should be
certified by a nationally authorized explosion-proof product certification
agency and have obtained an explosion-proof qualification certificate.
�. The certification parameters between the isolated safety barrier
and the on-site intrinsic safety instrument are clear and comply
with GB/T����.��, ���.�, etc.
�. If there are unclear parameters, it is necessary to form an intrinsically
safe circuit system and obtain explosion-proof products authorized by
the state confirmation from the certification body.
Intrinsically safe explosion-proof circuit system
National Quality Inspection and Testing Center for Explosion proof
Electrical Products (CQST)
Explosion proof sign: [Exia Ga] IIC
Certification number: CNEx��.����
Intrinsic safety parameter: Um=���VAC/DC
DRG-����(�-��)、DRG-����(�-��)
Uo=��VDC,lo=��mA,Po=���mW,Co=�.��μF,Lo=�.�mH
DRG-����(�-�)、DRG-����(�-�)
Uo=��.�VDC,lo=��mA,Po=���mW,Co=�.��μF,Lo=�.�mH
Safety and explosion-proof certification
【Product Features】: IC explosion-proof grade, wide range power
supply, in compliance with EMC standards
【Installation site】: The surrounding air should be free of corrosive
media that can corrode chromium, nickel, and silver coatings
【Applicable to site and equipment】: Installed in a safe place, it can
communicate with Zone � frequency equipment with IIA, IIB, and IIC
hazardous gases
【Overall dimensions】:
Base power supply: Width ��� × Height ��� × Depth��� (mm)
Terminal power supply: Width ��.� × Height ��� × Depth ��� (mm)
【Overall weight】: ���g
Structure and overall dimensions
【Number of Channels】: DRG-���� one in one out
DRG-���� one in two out
【Power supply voltage】: ��-��VDC
【Safety side input】:
Maximum distribution voltage for hazardous area
instruments: ��V optional
Minimum distribution voltage: �.�V (output ��mA)
Signal level: high level ≥ �V, low level ≤ �V
Frequency ≤ ��kHz, amplitude ≤ ��V, duty cycle ≥ ��%
【Dangerous side output】:
Signal level: Low level ≤ �.�V, high level ≥ �.�V
Drive current: ≤ ��mA
Load resistance: ≥ �K Ω
【Electromagnetic compatibility】:
In accordance with GB/T ����� (IEC �����-�)
【Insulation strength】:
����VAC/min between intrinsic safety end and non intrinsic
safety end
����VAC/min between non intrinsically safe terminals
【Output accuracy】: �.�% F.S
【Temperature drift】:�.��% F.S./C
【Power protection】: Power reverse protection
【Working temperature】: -�� ° C~+�� ° C
【Relative humidity】: ��% to ��% RH
【Storage temperature】: -�� ℃~+�� ℃
【Product Structure】: ��mm rail clamp type, PC+ABS flame-retardant
housing material, plug-in terminal
Performance index