User Manual
DRG-����, DRG-����, DRG-���� switch
input, relay output, isolated safety barrier
Before using this device, please read the instructions carefully and keep them properly for reference and reference. The color and appearance
may vary depending on the product. If the specifications are changed in the future for the purpose of improving performance, no further
notice will be given.
Accessory
�. Please check if all items are included in your product.
If there is any loss, please contact your sales personnel.
�. The color and shape of the object may vary depending
on the model.
�. The number of baffles provided may vary depending
on the quantity of products purchased.
Handbook
Others
Safety Barrier User
Manual X�
Blocking (depending
on the quantity of
products purchased)
Used to protect base terminals, a
group of fiveisolators.
To add, please contact the sales
staff to purchase separately.
Warning!
�. Read this manual carefully before installation and use; If in doubt, please contact us.
�. It is strictly prohibited to disassemble and install the instrument without permission to prevent instrument failure or failure.
�. The product shell holes are designed to provide the necessary heat dissipation, in order to ensure the reliable operation of the
product and prevent it from overheating, do not plug or cover these holes.
�. The surrounding environment must not have strong vibration, shock and large current and spark electromagnetic induction.
�. The air should not contain chromium, nickel, silver coating corrosion effect of the medium, should not contain flammable,
explosive substances.
�. Do not insert any metal objects into the hole of this product, otherwise it will cause short circuit.
�. For products with base, the exposed part of base terminal should be inserted with our matching block.
�. If the operation of this product is abnormal, especially if any unusual odor is emitted, please remove this product immediately and
contact the company.
Product description
Switching input isolation type safety barrier, receiving switch or
proximity switch inputs from hazardous areas, and transmitting
them to a safe place for output through safety barrier isolation,
with relay output normally open/normally closed conversion
setting function. This product requires independent power supply
and isolation of the power supply, input, and output terminals.
Technical parameter
【Current consumption】: DRG-���� � in � out
DRG-���� � in � out
DRG-���� � in � out
【Power supply voltage】: ��~��VDC
【Signal input characteristics】:
On site sensor side power supply voltage: approximately �V (when
open circuit)
When the on-site input current is>�.�mA, it indicates "ON"
When the on-site input current is less than �.�mA, it indicates "OFF"
Switch hysteresis effect: ���us
【Relay output characteristics】: Response time: ��ms
Drive capacity: ���VAC/�A, ��VDC/�A
【Input fault detection function (K� and � are set to ON)】:
When the input is disconnected or short circuited, the output relay
is disconnected and the red indicator light is on.
【Switch setting function】:
K�(output �),K�(output �)
State
Inverted input and output
Input and output in phase
K�(output �),K�(output �)
Equipped with line fault
detection function
No line fault detection function
Note: For switch input (�), K� and K� need to be set to the OFF state,
and there is no line fault (disconnection, short circuit) detection
function; If there is a need for line fault (wire breakage, short circuit)
detection function, a ��K ٠resistor should be connected in parallel
at both ends of the switch, and a ��� ٠resistor should be connected
in series, as shown in switch (II). K� and K� should be set to the ON
state.
◆ Performance indicators
Electromagnetic compatibility:
In accordance with GB/T ����� (IEC �����-�)
【Insulation strength】:
����VAC/min between intrinsic safety end and non intrinsic
safety end
����VAC/min between non intrinsically safe terminals
◆ Structure and overall dimensions
【Overall dimensions】:
Base power supply: Width ��.� × Height ��� ×Depth ��� (mm)
Terminal power supply: Width ��.� × Height ��� × Depth ��� (mm)
【 Overall weight 】: ���g
【 Product Features 】: Wide range power supply, in compliance with
EMC standards
【 Installation site 】: The surrounding air should be free of corrosive
media that can corrode chromium, nickel, and silver coatings
【Applicable to site and equipment】: Zone �, Zone �, Zone �, IA, IB,
IC hazardous areas, in accordance with DIN����� and NAMUR
proximity switches, switches, and other on-site equipment
National Quality Inspection and Testing Center for Explosion proof
Electrical Products (CQST)
Explosion proof sign: [Exia Ga] IIC
Certification number: CNEx��.����
Intrinsic safety parameter:
DRG-����、DRG-����(��-��)
Um=���VAC/DC,Uo=��.�VDC,lo=��mA,Po=��mW,Co=�.�μF,Lo=���mH
DRG-����(��-��、��-��)
Um=���VAC/DC,Uo=��.�VDC,lo=��mA,Po=��mW,Co=�.�μF,Lo=���mH
Safety and explosion-proof certification
The isolation type safety barrier and the on-site intrinsic safety
instrument are connected to form an intrinsic safety explosion-proof
circuit (intrinsic safety circuit). The system must confirm before use:
�. The explosion-proof level of on-site intrinsically safe instruments
should comply with the operating environment, and they should be
certified by a nationally authorized explosion-proof product
certification agency and have obtained an explosion-proof
qualification certificate.
�. The certification parameters between the isolated safety barrier
and the on-site intrinsic safety instrument are clear and comply with
GB/T����.��, ���.�, etc.
�. If there are unclear parameters, it is necessary to form an intrinsically
safe circuit system and obtain explosion-proof products
authorized by the state confirmation from the certification body.
Intrinsically safe explosion-proof circuit system
【Power protection】: Power reverse protection
【Working temperature】: -�� ℃~+�� ℃
【Relative humidity】: ��% to ��% RH
【Storage temperature 】: -�� ℃~+�� ℃
【Product Structure】: ��mm rail clamp type, PC+ABS flame-retardant
housing material, plug-in terminal
Using Tutorials WeChat official account
Address: ��th to ��th floors, Building �, No. ��Dongcun Road,
Jiangning District, Nanjing City
Central:���-��������/����
Website: http://www.cn-paragon.com
Technical support:�����������
E-mail: [email protected]