Monitoring the Unit
4-9
7976-A2-GB20-10
August 1998
This Field . . .
Contains . . .
Current interval
timer
The number of seconds which have elapsed in the current
15-minute interval. Maximum value is 900 seconds (15 minutes).
This counter resets every 15 minutes.
Payload Rate
The Payload Rate across the DSL interface. Refer to Table 3-4,
Fixed Rate Payload Rates and DSL Line Rates
, in Chapter 3,
Initial Startup and Configuration.
DSL Line Rate
The rate of the DSL line. The line rate can be 400, 528, 784,
1040, 1552, or 2064 kbps.
Current Interval
Performance data for the current 15 minutes.
Interval
xx
Historical performance data for up to 96 15-minute intervals
(24 hours) where the value of
xx is from 01 to 96.
Network Performance Statistics are collected for:
H
Mrgn: Margin, the signal-to-noise ratio (SNR) less an SNR reference value.
H
XmtPw: The transmit power level.
H
RxGn: The receiver gain level.
H
Complete: Whether the interval register contains data for a complete
900-second interval.