Monitoring the Unit
4-5
7976-A2-GB20-10
August 1998
Self-Test Results
The results of the last power-up or reset self-test appear in the middle column of
the System and Test Status screen.
Table 4-2.
Self-Test Results Messages
Message
What Message Indicates
What To Do
CPU Failed
The CPU failed internal testing.
1. Reset the unit and try again.
Device
Failed
One or more of the Unit’s integrated
circuit chips failed device-level
testing.
2. Call your service
representative for assistance.
G.703
Failed, Pt 1
The Unit failed to loop data on the
G.703 on Port 1.
1. Reset the unit and try again.
2. Call your service
Memory
Failed
The Model 7976 Standalone
Termination Unit failed memory
verification.
2. Call your service
representative for assistance.
FPGA
Failed, Pt1
A failure in the FPGA was detected.
1. Reset the unit and try again.
2. Call your service
representative for assistance.
DataPath
Failed, Pt1
The unit failed to loop data between
the G.703 Port and the DSL loop.
1. Reset the unit and try again.
2. Call your service
representative for assistance.
Failure
xxxxxxxx
An internal failure occurred.
(xxxxxxxx represents an eight-digit
hexadecimal failure code for use by
service personnel.)
Record the failure code and
contact your service
representative.
Passed
No errors were detected.
Summary of Contents for Hotwire 7976
Page 56: ...Monitoring the Unit 4 14 7976 A2 GB20 10 August 1998 This page intentionally left blank...
Page 66: ...Testing 5 10 7976 A2 GB20 10 August 1998 This page intentionally left blank...
Page 78: ...Security 7 6 7976 A2 GB20 10 August 1998 This page intentionally left blank...
Page 104: ...Standards Compliance for SNMP Traps B 6 7976 A2 GB20 10 August 1998...
Page 112: ...Technical Specifications D 2 7976 A2 GB20 10 August 1998...