Standards Compliance for SNMP Traps
B-2
7976-A2-GB20-10
August 1998
linkUp and linkDown
The link SNMP traps are:
H
linkUp – The unit recognizes that one of the communication interfaces is
operational.
H
linkDown – The unit recognizes that one of the communication interfaces is
not operational.
The network and synchronous port interfaces (physical sublayer) are represented
by an entry in the MIB-II interfaces table and supported by the DS1 MIB.
The following list describes the conditions that define linkUp and linkDown:
linkUp/Down Variable-Bindings
H
ifIndex (RFC 1573)
This object provides the index into the ifTable and potentially into tables in other MIBs.
The values of ifIndex are the same for all models, although not all indexes are
supported for each model.
The ifIndex included with the trap consists of:
– 1
COM Port
– 2
SDSL E1 Interface, Port 1
– 6
G.703 Interface, Port 1
H
ifAdminStatus (RFC 1573)
This object specifies the operational state of the interface:
– up(1)
SDSL Network: DSL link is established.
G.703: No alarm condition exists.
– down(2)
SDSL Network: DSL link is not established.
G.703: An alarm condition exists.
– testing(3)
A test is active on the interface.
H
ifOperStatus (RFC 1573)
This object contains the same value as ifAdminStatus.
H
i
fType (RFC 1573)
This object is the type of interface:
– e1(19)
Used for the G.703 E1 interface.
Summary of Contents for Hotwire 7976
Page 56: ...Monitoring the Unit 4 14 7976 A2 GB20 10 August 1998 This page intentionally left blank...
Page 66: ...Testing 5 10 7976 A2 GB20 10 August 1998 This page intentionally left blank...
Page 78: ...Security 7 6 7976 A2 GB20 10 August 1998 This page intentionally left blank...
Page 104: ...Standards Compliance for SNMP Traps B 6 7976 A2 GB20 10 August 1998...
Page 112: ...Technical Specifications D 2 7976 A2 GB20 10 August 1998...