Configuration
8-5
9124-A2-GH30-00
June 1999 - Preliminary
Minimal Configuration Before Deploying Remote Units
At a minimum, the following configuration options must be set before deploying a
a FrameSaver unit to a remote site:
H
Node IP Address
H
Node Subnet Mask
See
Configuring Node IP Information
in Chapter 8, Configuration Options, for
these options.
Entering and Displaying System Information
Use the Device Name screen to name the system, and to change or display the
general SNMP system name, location, and contact for the unit.
"
Procedure
1. Follow this menu selection sequence:
Main Menu
→
Control
→
System Information
2. Move the cursor to the field ( Tab to the field, or press the arrow keys ) where
you want to add or change information.
The following information is available for viewing. Use the right and left arrow
keys to scroll additional text into view.
If the selection is . . .
Enter the . . .
Device Name
Unique name for device identification of up to
20 characters.
System Name
SNMP system name; can be up to 255 characters.
System Location
System’s physical location; can be up to 255 characters.
System Contact
Name and how to contact the system person; can be up to
255 characters.
Date
Current date in the month/day/year format (mm/dd/yyyy).
Time
Current time in
the hours:minutes format (hh:mm).
NOTE:
To clear existing information, place the cursor in the Clear field ( Tab to
the Clear field ) and press Enter.
3. Press Ctrl-a and Save your entriesSetting Up LoginsSee Chapter 9,
Security
,
to set up and administer logins.