10
Installation Overview
Installation and configuration of the T1 or E1 Line Card consists of:
❑
Obtain the applicable cable; refer to
Cabling
on page 13
for part numbers.
❑
Make sure the BLC is installed and power is supplied to the chassis.
❑
Install the card in the BLC.
❑
Connect to the T1 or E1 uplink.
❑
Configure your unit using the web or TL1 interface. Refer to the SCP card’s online
Help or the
8620 and 8820 Broadband Loop Carrier TL1 Reference
for
configuration information.
Be sure to register your warranty at
www.paradyne.com/warranty
.
Installing T1 and E1 Line Cards
HANDLING PRECAUTIONS FOR
STATIC-SENSITIVE DEVICES
This product is designed to protect sensitive
components from damage due to electrostatic
discharge (ESD) during normal operation. When
performing installation procedures, however,
take proper static control precautions to prevent
damage to equipment. If you are not sure of the
proper static control precautions, contact your
nearest sales or service representative.
A T1 or E1 Line Card can be installed in, removed from, and replaced in a BLC without
disrupting service to the other cards in the chassis.
Procedure
To install the T1 or E1 Line Card:
1.
Determine in which slot the unit will be installed. Verify that cards in adjacent slots
have been fastened.
2.
Remove the filler plate from the installation slot and store for possible later use.
!